Additional information
Additional information on how to commission an NX component is provided in:
• Commissioning Manual IBN CNC: NCK, PLC, Drive
See also
Connecting digital inputs/outputs (Page 86)
12.1.5 Technical Data
Table 12-9 Safety-related data
Protection class III
Degree of protection to EN 60529 IPXXB
Approvals CE, cULus
Pollution degree 2
Cooling Open-circuit ventilation
Mounting position Vertical
PE/ground connection at the housing with M5 screw Torx / 3 Nm
Table 12-10 Electrical and mechanical data
Input voltage 24 V DC (20.4 – 28.8)
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current 3.35 A
Power loss 15 W
Dimensions WxHxD (with spacers) 25 x 414 x 272 mm
Weight 2.58 kg
12.2 PP 72/48D PN
12.2.1 Description
Characteristics
I/O module PP 72/48D PN is a simple module (without a separate housing) for connecting digital
input/outputs as part of an automation system based on PROFINET IO.
Connectable components
12.2 PP 72/48D PN
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE 111