EasyManua.ls Logo

Siemens Sirius 3UG4614 User Manual

Siemens Sirius 3UG4614
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GWA 4NEB 927 0403-10 DS 02 Last update: 15 September 2006
Vor der Installation, dem Betrieb oder der Wartung des Geräts muss diese Anleitung gelesen und verstanden werden.
Read and understand these instructions before installing, operating, or maintaining the equipment.
Ne pas installer, utiliser ou intervenir sur cet équipement avant d'avoir lu et assimilé ces instructions.
Leer y comprender este instructivo antes de la instalación, operación o mantenimiento del equipo.
Leggere con attenzione queste istruzioni prima di installare, utilizzare o eseguire manutenzione su questa apparecchiatura.
Ler e compreender estas instruções antes da instalação, operação ou manutenção do equipamento.
Eine sichere Gerätefunktion ist nur mit zertifizierten Komponenten gewährleistet.
Reliable functioning of the equipment is only ensured with certified components.
Le fonctionnement sûr de l'appareil n'est garanti qu'avec des composants certifiés.
El funcionamiento seguro del aparato sólo está garantizado con componentes certificados.
Il funzionamento sicuro dell'apparecchiatura è garantito soltanto con componenti certificati.
O funcionamento seguro do aparelho apenas pode ser garantido se forem utilizados os componentes certificados.
GEFAHR DANGER DANGER
Gefährliche Spannung.
Lebensgefahr oder schwere
Verletzungsgefahr.
Vor Beginn der Arbeiten Anlage und
Gerät spannungsfrei schalten.
Hazardous voltage.
Will cause death or serious injury.
Disconnect power before working
on equipment.
Tension dangereuse.
Danger de mort ou risque de blessures
graves.
Mettre hors tension avant d’intervenir sur
l’appareil.
PELIGRO PERICOLO PERIGO
Tensión peligrosa.
Puede causar la muerte o lesiones
graves.
Desconectar la alimentación eléctrica antes
de trabajar en el equipo.
Tensione pericolosa.
Può provocare morte o lesioni gravi.
Scollegare l’alimentazione prima di
eseguire interventi sull’apparecchiatura.
Tensão perigosa.
Perigo de morte ou ferimentos graves.
Desligue a corrente antes de
trabalhar no equipamento.
! ! !
! ! !
SIRIUS
Überwachungsrelais zur Phasenfolge-, Asymmetrie- und Unterspannungsüberwachung
Monitoring Relays for Phase-Sequence, Asymmetry and Voltage Monitoring
Relais de surveillance pour l’ordre, la surveillance de tension asymétrique et minimum de tension
Relé de vigilancia de secuencias, asimetría y mínima tensión
Relè di sorveglianza della sequenza delle fasi e, sorveglianza del sottovoltaggio
Relé de monitorização para vigilância de seqüência das fases e, vigilância subtensão e tensão assimétrica
3UG4614
Betriebsanleitung Operating Instructions Instructions de service
Instructivo Istruzioni operative Instruções de Serviço
Bestell-Nr./Order No.: 3ZX1012-0UG46-6AA1
EN 60 947, IEC 60 947
1. U = 0 V
2. a, b, c, d
3RP1903
b
c
a
b
d
A, B, C
Kodiert
Coded
Codé
Cifrado
Codificato
Codificado
A
C
B
2
3
5
4
~10°
~10°
1
DIN ISO 2380 -1A 0,5 x 3
3mm
1
2
3
3RP1902
4
4
5
Question and Answer IconNeed help?

Do you have a question about the Siemens Sirius 3UG4614 and is the answer not in the manual?

Siemens Sirius 3UG4614 Specifications

General IconGeneral
Product brand nameSiemens
Product designation3UG4614
Design of the productMonitoring relay
Product function: Short-circuit monitoringYes
Product function: Broken wire monitoringYes
Insulation voltage rated value300 V
Degree of pollution3
Surge voltage resistance rated value4 kV
Protection class IPIP20
Operating frequency rated value50/60 Hz
Operating range factor control supply voltage rated value at AC at 50 Hz0.85 ... 1.1
Operating range factor control supply voltage rated value at AC at 60 Hz0.85 ... 1.1
Number of NC contacts delayed switching0
Number of NO contacts delayed switching1
Number of CO contacts delayed switching0
Number of NC contacts instantaneous contact0
Number of NO contacts instantaneous contact0
Number of CO contacts instantaneous contact0
Operating current at AC-15 at 230 V rated value3 A
Width22.5 mm
TypeMonitoring relay
Frequency range50/60 Hz
Operating range factor control supply voltage rated value at DC0.8...1.1
Mechanical service life (switching cycles) typical10000000
Electrical endurance (switching cycles) at AC-15 at 230 V typical100000
Type of electrical connectionScrew terminals
Tightening torque0.5 Nm
Ambient temperature during operation-25 ... 60 °C
Ambient temperature during storage-40 ... 85 °C
Relative humidity during operation5...95 %
Contact configuration1 NO
Operating temperature range-25...55 °C
Output TypeRelay
Mounting TypeDIN rail
Make time100 ms
Type of connectable conductor cross-sections0.25 ... 2.5 mm²

Summary

General Safety Warnings

Hazardous Voltage Danger

Warnings regarding dangerous voltage that can cause death or serious injury. Disconnect power before work.

Dangerous Voltage Warning

Warnings about dangerous voltage, potentially causing death or severe injuries. Ensure power disconnection before servicing.

Product Description and Monitoring Functions

Monitoring Functions Overview

Details the relay's monitoring capabilities including phase sequence, phase failure, voltage, and asymmetry.

Function Diagrams

Closed-Circuit Principle Diagrams

Illustrates relay operation under closed-circuit principle for various fault conditions and delays.

Working-Current Principle Diagrams

Illustrates relay operation under working-current principle for various fault conditions and delays.

Menu Navigation Guide

Run and Value Settings

Guide to navigating the 'Run' display and adjusting operational values like voltage and asymmetry.

Set and Error Modes

Guide to configuring settings, understanding error messages, and resetting the device.

Technical Specifications and Dimensions

Dimensions and Wiring Information

Provides physical dimensions, mounting details, and terminal specifications for wire connections.

Technical Support Contacts

Contact information for technical assistance and support via phone, email, and internet.

Related product manuals