Product brand name | Siemens |
---|---|
Product designation | 3UG4614 |
Design of the product | Monitoring relay |
Product function: Short-circuit monitoring | Yes |
Product function: Broken wire monitoring | Yes |
Insulation voltage rated value | 300 V |
Degree of pollution | 3 |
Surge voltage resistance rated value | 4 kV |
Protection class IP | IP20 |
Operating frequency rated value | 50/60 Hz |
Operating range factor control supply voltage rated value at AC at 50 Hz | 0.85 ... 1.1 |
Operating range factor control supply voltage rated value at AC at 60 Hz | 0.85 ... 1.1 |
Number of NC contacts delayed switching | 0 |
Number of NO contacts delayed switching | 1 |
Number of CO contacts delayed switching | 0 |
Number of NC contacts instantaneous contact | 0 |
Number of NO contacts instantaneous contact | 0 |
Number of CO contacts instantaneous contact | 0 |
Operating current at AC-15 at 230 V rated value | 3 A |
Width | 22.5 mm |
Type | Monitoring relay |
Frequency range | 50/60 Hz |
Operating range factor control supply voltage rated value at DC | 0.8...1.1 |
Mechanical service life (switching cycles) typical | 10000000 |
Electrical endurance (switching cycles) at AC-15 at 230 V typical | 100000 |
Type of electrical connection | Screw terminals |
Tightening torque | 0.5 Nm |
Ambient temperature during operation | -25 ... 60 °C |
Ambient temperature during storage | -40 ... 85 °C |
Relative humidity during operation | 5...95 % |
Contact configuration | 1 NO |
Operating temperature range | -25...55 °C |
Output Type | Relay |
Mounting Type | DIN rail |
Make time | 100 ms |
Type of connectable conductor cross-sections | 0.25 ... 2.5 mm² |
Warnings regarding dangerous voltage that can cause death or serious injury. Disconnect power before work.
Warnings about dangerous voltage, potentially causing death or severe injuries. Ensure power disconnection before servicing.
Details the relay's monitoring capabilities including phase sequence, phase failure, voltage, and asymmetry.
Illustrates relay operation under closed-circuit principle for various fault conditions and delays.
Illustrates relay operation under working-current principle for various fault conditions and delays.
Guide to navigating the 'Run' display and adjusting operational values like voltage and asymmetry.
Guide to configuring settings, understanding error messages, and resetting the device.
Provides physical dimensions, mounting details, and terminal specifications for wire connections.
Contact information for technical assistance and support via phone, email, and internet.