Technical data
6.2 Output
SITOP PSU300S
Manual, 12.2016, C98130-A7587-A1-7-7629
39
Figure 6-5 Output characteristic 6EP1436-2BA10
Figure 6-6 Output characteristic 6EP1437-2BA20
The device supplies a constant output voltage until the current limit is reached. In the event
of an overload, the output current and the output voltage are reduced.
For 6EP1436-2BA10 and 6EP1437-2BA20, the following applies: When the output voltage
falls below approx. 10 V, the device switches off, and initiates an automatic restart. This
response is repeated as long as the overload condition is present.