EasyManua.ls Logo

Siemens SITOP PSU8200 24 V/20 A User Manual

Siemens SITOP PSU8200 24 V/20 A
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SITOP power supply
SITOP PSU8200/3800 3ph
Manual
SITOP PSU8200 24 V/20 A
6EP3436
-8SB00-0AY0
SITOP PSU8200 24
V/40 A
6EP1437
-3BA10
SITOP PSU8
200 24 V/40 A
6EP3437
-8SB00-0AY0
SITOP PSU8200 36 V/13 A
6EP3446
-8SB10-0AY0
SITOP PSU8200 48
V/10 A
6EP3446
-8SB00-0AY0
SITOP PSU8200 48 V/20 A
6EP3447
-8SB00-0AY0
SITOP PSU3800 12 V/20 A
6EP3424
-8UB00-0AY0
SITOP PSU3800 24 V/17 A
6EP3436
-8UB00-0AY0
SITOP PSU3800 24
V/40 A
6EP3437
-8UB00-0AY0
05.2018
C98130
-A7638-A1-6-7629
Overview
Notes on safety
1
Description, device design,
dimension drawing
2
Mounting/removing
3
Mounting position, mounting
clearances
4
Installation
5
Technical data
6
Safety, approvals, EMC
7
Ambient conditions
8
Applications
9
Environment
10
Service & Support
11

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SITOP PSU8200 24 V/20 A and is the answer not in the manual?

Siemens SITOP PSU8200 24 V/20 A Specifications

General IconGeneral
Output Current20 A
Output Power480 W
Input Voltage85-264 V AC (47-63 Hz), 88-350 V DC
Output Voltage24 V DC
Operating Temperature-25 to +70 °C
Protection FeaturesOverload, overvoltage, short-circuit protection
Dimensions125 mm x 125 mm x 130 mm (W x H x D)
Cooling MethodConvection

Summary

Overview

Notes on safety

General safety instructions

General safety instructions for handling electrical devices safely.

Safety instructions for hazardous zones

Specific safety instructions for operating devices in hazardous areas.

Description, device design, dimension drawing

Device description

Detailed description of the SITOP PSU8200/3800 3ph power supply.

Connections and terminal designation

Explanation of input and output terminals and their designations.

Potentiometer

Information on using the potentiometer to adjust output voltage.

Status displays and signaling

Description of LEDs and signaling contacts for device status.

Change-over switch

Details on the function of the selector switches A and B.

Block diagram

Diagram illustrating the internal functional blocks of the power supply.

Dimensions and weight

Physical dimensions and weight specifications for various models.

Mounting/removing

Mounting position, mounting clearances

Standard mounting position

Guidelines for standard vertical mounting and clearances.

Other mounting positions

Derating factors for positions deviating from standard mounting.

Installation

Line-side connection

Instructions for connecting the power supply to the 3-phase AC line.

Output-side connection

Details on connecting the load to the DC output terminals.

Technical data

Input

Specifications related to the AC input of the power supply.

Output

Specifications related to the DC output of the power supply.

Efficiency

Data on power conversion efficiency and losses.

Closed-loop control

Technical data on the dynamic response of the control loop.

Protection and monitoring

Specifications for built-in protection and monitoring functions.

MTBF

Mean Time Between Failures data for reliability assessment.

Mechanical system

Details on connection systems, dimensions, and mounting.

Accessories

List of available electrical and mechanical accessories.

Dimension drawing

References to CAD data for dimension drawings.

Safety, approvals, EMC

Safety

General safety information and product compliance details.

Test voltage

Test voltages applied for safety certification.

Approvals

List of certifications and approvals obtained by the product.

EMC

Electromagnetic compatibility standards and test parameters.

Ambient conditions

Ambient temperature

Operating temperature ranges and derating conditions.

Transport and storage temperature

Temperature limits for transport and storage.

Humidity class

Humidity class requirements for operation.

Mechanical stressing during operation

Specifications for vibration and shock resistance.

Damaging gases

Testing for resistance against damaging gases.

Atmospheric pressure

Operating and storage atmospheric pressure conditions.

Applications

Parallel connection to increase power rating

How to connect multiple power supplies in parallel for higher output.

Parallel connection for redundancy

Configuring power supplies in parallel for increased system availability.

Series connection for increased voltage

Connecting power supplies in series to achieve higher output voltage.

Overload protection in the 24 V output circuit

Methods for overload protection in 24 V output circuits.

Protection against short-time voltage dips

Using buffer modules to maintain output during voltage dips.

Protecting against longer power failures

Using DC-UPS solutions for buffering longer power failures.

Battery charging with SITOP PSU3800

Using PSU3800 for charging lead batteries.

Environment

Disposal guidelines

Guidelines for recycling packaging and product disposal.

Service & Support

Technical support

Contact channels for technical assistance and support.

Technical documentation on the Internet

Accessing operating instructions and manuals online.

SITOP power supply homepage

Information and news about SITOP power supplies.

Information material

Downloading SITOP information from the Internet.

CAx data

Downloading 2D/3D data and circuit diagram macros.

SITOP Selection Tool

Tool for selecting optimum power supply or DC-UPS.

Online catalog and ordering system

Accessing the online catalog and ordering system.

Contact persons

Finding regional Siemens sales office contact information.

Related product manuals