EasyManua.ls Logo

Siemens SITOP PSU8200 24 V/20 A - Status displays and signaling

Siemens SITOP PSU8200 24 V/20 A
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description, device design, dimension drawing
2.4 Status displays and signaling
SITOP PSU8200/3800 3ph
14 Manual, 05.2018, C98130-A7638-A1-6-7629
2.4
Status displays and signaling
6EP3436-8SB00-0AY0
(24 V/20 A)
6EP1437-3BA10
(24 V/40 A)
6EP3437-8SB00-0AY0
(24 V/40 A)
Operating display
LED green for "24 V O.K."
Yellow LED for overload in
"constant current" mode
Red LED for latching shut-
down in the "Shut down"
mode, for Remote OFF or for
overtemperature
(LED flashes)
LED green for "24 V O.K."
Yellow LED for overload in
"constant current" mode
Red LED for latching shut-
down in "shut down" mode
LED green for "24 V O.K."
Yellow LED for overload in
"constant current" mode
Red LED for latching shut-
down in the "Shut down"
mode, for Remote OFF or for
overtemperature
(LED flashes)
Signaling contact 13, 14
Relay contact (NO contact,
contact rating (isolated):
30 V AC/0.5 A, 60 V
DC/0.3 A, 30 V DC/1 A) for
"24 V O.K."
Relay contact (NO contact,
contact rating (isolated):
30 V AC/0.5 A, 60 V
DC/0.3 A, 30 V DC/1 A) for
"24 V O.K."
Relay contact (NO contact,
contact rating (isolated):
30 V AC/0.5 A, 60 V
DC/0.3 A, 30 V DC/1 A) for
"24 V O.K."
Remote contact 15, 16
Non-isolated input for remote
ON/OFF switching of the
power supply. Function: The
device is remotely switched
off when contacts 15, 16 are
short-circuited (R < 8 kΩ).
- Isolated input for remote
ON/OFF switching of the
power supply.
Function: The device is re-
motely switched off when
contacts 15, 16 are short-
circuited (R < 8 ).
6EP3446-8SB10-0AY0
(36 V/13 A)
6EP3446-8SB00-0AY0
(48 V/10 A)
6EP3447-8SB00-0AY0
(48 V/20 A)
Operating display
LED green for "36 V O.K."
Yellow LED for overload in
"constant current" mode
Red LED for latching shut-
down in the "Shut down"
mode, for Remote OFF or for
overtemperature
(LED flashes)
LED green for "48 V O.K."
Yellow LED for overload in
"constant current" mode
Red LED for latching shut-
down in the "Shut down"
mode, for Remote OFF or for
overtemperature
(LED flashes)
LED green for "48 V O.K."
Yellow LED for overload in
"constant current" mode
Red LED for latching shut-
down in the "Shut down"
mode or for Remote OFF
Signaling contact 13, 14
Relay contact (NO contact,
contact rating (isolated):
30 V AC/0.5 A, 60 V
DC/0.3 A, 30 V DC/1 A) for
"36 V O.K."
Relay contact (NO contact,
contact rating (isolated):
30 V AC/0.5 A, 60 V
DC/0.3 A, 30 V DC/1 A) for
"48 V O.K."
Relay contact (NO contact,
contact rating (isolated):
30 V AC/0.5 A, 60 V
DC/0.3 A, 30 V DC/1 A) for
"48 V O.K."
Remote contact 15, 16
Non-isolated input for remote
ON/OFF switching of the
power supply. Function: The
device is remotely switched
off when contacts 15, 16 are
short-circuited (R < 8 kΩ).
Non-isolated input for remote
ON/OFF switching of the
power supply. Function: The
device is remotely switched
off when contacts 15, 16 are
short-circuited (R < 8 kΩ).
Isolated input for remote
ON/OFF switching of the
power supply.
Function: The device is re-
motely switched off when
contacts 15, 16 are short-
circuited (R < 8 ).

Table of Contents

Related product manuals