SITOP power supplies
SITOP UPS1600 / UPS1100
Manual
SITOP UPS1600 10 A
6EP4134
-3AB00-0AY0
6EP4134
-3AB00-1AY0
6EP4134
-3AB00-2AY0
SITOP UPS160
0 20 A
6EP4136
-3AB00-0AY0
6EP4136
-3AB00-1AY0
6EP4136
-3AB00-2AY0
SITOP UPS1600 40 A
6EP4137
-3AB00-0AY0
6EP4137
-3AB00-1AY0
6EP4137
-3AB00-2AY0
SITOP UPS1100
Battery module 1.2
Ah
6EP4131
-0GB00-0AY0
Battery module 2.5 Ah
6EP4132
-0GB00-0AY0
Bat
tery module 3.2 Ah
6EP4133
-0GB00-0AY0
Battery module 5 Ah
6EP4133
-0JB00-0AY0
Battery module 7 Ah
6EP4134
-0GB00-0AY0
Battery module 12 Ah
6EP4135-0GB00-0AY0
04.2017
A5E3777
5406-8-76
Overview
Safety instructions
1
Description, device design,
dimension drawing
2
Engineering and remote
access
3
Troubleshooting
4
Mounting/removing
5
Mounting position, mounting
clearances
6
Installation
7
Technical data
8
Safety, approvals, EMC
9
Environmental conditions
10
Environment
11
Service & Support
12

Table of Contents

Other manuals for Siemens SITOP UPS1600

Questions and Answers

  • W
    webstermichaelSep 6, 2025
    What does unknown parameter mean on Siemens UPS?
    • L
      Lawrence ChanSep 6, 2025
      Attempting to set a parameter that is not known by Siemens DC UPS.
  • N
    Nicolas BallAug 25, 2025
    Why is buffer mode not possible on my Siemens UPS?
    • B
      Brandon SheltonAug 25, 2025
      If buffer mode is not possible on your Siemens UPS, check settings, cabling, fuse, and battery voltages.
  • C
    Christopher SimmonsAug 25, 2025
    How to fix Siemens UPS device temperature too low?
    • M
      mary39Aug 26, 2025
      If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
  • J
    jonathan46Sep 14, 2025
    Why Siemens UPS input voltage is too high?
    • J
      Jesse TuckerSep 14, 2025
      Siemens DC UPS is not operational.
  • W
    Wendy JohnsonSep 23, 2025
    Why is the battery not available on my Siemens Power Supply?
    • J
      Joshua HenrySep 23, 2025
      The Siemens Power Supply is attempting to access a battery that is not available because it was never connected, or communication with this battery was interrupted.
  • L
    Lauren EllisSep 10, 2025
    What does EEPROM write error mean on Siemens UPS?
    • C
      clarkbruceSep 12, 2025
      The Siemens UPS device is defective.
  • A
    amandajonesSep 2, 2025
    What does wrong parameter mean on Siemens UPS?
    • A
      Ann WalkerSep 2, 2025
      The parameter value lies outside the valid range on your Siemens UPS.
  • H
    henrymelindaSep 2, 2025
    What does wrong checksum mean on Siemens UPS?
    • J
      Jose HowardSep 2, 2025
      Communication disrupted with your Siemens UPS.
  • C
    Christopher AllenSep 18, 2025
    What causes 'Communication error: Wrong length field' on Siemens SITOP UPS1600?
    • R
      robertsdawnSep 18, 2025
      This error means there's a syntax error in the command sent to the Siemens Power Supply.
  • M
    Melissa SmithAug 28, 2025
    What does insufficient charge level mean on Siemens UPS?
    • T
      Travis NavarroAug 29, 2025
      The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.

Summary

Safety Instructions and Warnings

Warning Notice System

Explains hazard grading (DANGER, WARNING, CAUTION, NOTICE) and safety alert symbols.

Qualified Personnel and Proper Use

Defines requirements for qualified personnel and proper Siemens product usage.

SITOP UPS Description and Design

SITOP UPS1600 Device Description

Details the SITOP UPS1600, its mounting, overload capability, and energy storage link.

Engineering and Remote Access

SIMATIC STEP 7 in TIA Portal Integration

Details using SIMATIC STEP 7 and TIA Portal for configuration, parameterization, and diagnostics.

SITOP UPS Manager Software Functions

Explains the functions and user interface of the SITOP UPS Manager software for configuration and monitoring.

Web Server Monitoring and Configuration

Covers accessing and configuring the device via a web browser interface for monitoring and control.

Troubleshooting and Fault Diagnosis

Hardware Fault Diagnosis

Lists common hardware faults, their causes, and troubleshooting steps with LED indicators.

Mounting and Removing Devices

Installation Procedures

Connecting SITOP UPS1600 Input and Output

Details the procedure for connecting power supply to SITOP UPS1600 input and output terminals.

Connecting SITOP UPS1100 Battery Modules

Explains how to connect SITOP UPS1100 battery modules to the SITOP UPS1600 using BAT connections.

Battery Maintenance and Replacement

Explains battery maintenance, replacement procedures, and battery types used.

Safety Approvals and EMC Compliance

Device Safety and Protection

Details safety protection classes and degree of protection ratings for the devices.

Siemens SITOP UPS1600 Specifications

General IconGeneral
Output Current40 A
Output Power960 W
Protection ClassIP20
Output Voltage24 V DC
Operating Temperature0°C to +40°C
InterfacesUSB
Efficiency>94% (typical)