What does unknown parameter mean on Siemens UPS?
- LLawrence ChanSep 6, 2025
Attempting to set a parameter that is not known by Siemens DC UPS.

What does unknown parameter mean on Siemens UPS?
Attempting to set a parameter that is not known by Siemens DC UPS.
Why is buffer mode not possible on my Siemens UPS?
If buffer mode is not possible on your Siemens UPS, check settings, cabling, fuse, and battery voltages.
How to fix Siemens UPS device temperature too low?
If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
Why Siemens UPS input voltage is too high?
Siemens DC UPS is not operational.
Why is the battery not available on my Siemens Power Supply?
The Siemens Power Supply is attempting to access a battery that is not available because it was never connected, or communication with this battery was interrupted.
What does EEPROM write error mean on Siemens UPS?
The Siemens UPS device is defective.
What does wrong parameter mean on Siemens UPS?
The parameter value lies outside the valid range on your Siemens UPS.
What does wrong checksum mean on Siemens UPS?
Communication disrupted with your Siemens UPS.
What causes 'Communication error: Wrong length field' on Siemens SITOP UPS1600?
This error means there's a syntax error in the command sent to the Siemens Power Supply.
What does insufficient charge level mean on Siemens UPS?
The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.
| Output Current | 40 A |
|---|---|
| Output Power | 960 W |
| Protection Class | IP20 |
| Output Voltage | 24 V DC |
| Operating Temperature | 0°C to +40°C |
| Interfaces | USB |
| Efficiency | >94% (typical) |
Explains hazard grading (DANGER, WARNING, CAUTION, NOTICE) and safety alert symbols.
Defines requirements for qualified personnel and proper Siemens product usage.
Details the SITOP UPS1600, its mounting, overload capability, and energy storage link.
Details using SIMATIC STEP 7 and TIA Portal for configuration, parameterization, and diagnostics.
Explains the functions and user interface of the SITOP UPS Manager software for configuration and monitoring.
Covers accessing and configuring the device via a web browser interface for monitoring and control.
Lists common hardware faults, their causes, and troubleshooting steps with LED indicators.
Details the procedure for connecting power supply to SITOP UPS1600 input and output terminals.
Explains how to connect SITOP UPS1100 battery modules to the SITOP UPS1600 using BAT connections.
Explains battery maintenance, replacement procedures, and battery types used.
Details safety protection classes and degree of protection ratings for the devices.