25
Interface description
Interference immunity
The connecting cable must not exceed
1.8m in length.
Nominal signal range: ±15V
Max. load current 1A
Electrical fast transient burst
requirements not specified
Surge immunity requirements not
specified
Electrostatic discharge requirements in
accordance with ETS 300-342-1
Immunity RF common mode
0.15–80MHz in accordance with
ETS300-342-1
Connectible RS232 connecting cable
Item Order
no.
Supplier
RS232 connecting cable
9-pin D-Sub
extension 1:1
300574 Tecline
Behrener Str. 8
D-66117 Saarbrücken
Tel.:+49(0)68192678-29
Fax:+49(0)68192678-50