Do you have a question about the Siemens ULTRAMAT 6F and is the answer not in the manual?
Measurement Principle | Non-Dispersive Infrared (NDIR) |
---|---|
Protection Class | IP54 |
Output Signal | 4-20 mA |
Communication | RS-232, RS-485 |
Power Supply | 24 V DC |
Measuring Components | CO, CO2, CH4, NO, SO2, NH3, H2O |
Summarizes essential features, functions, and safety info for safe device use.
Lists Series 6 devices and details their ATEX approval for hazardous area operation.
Covers device operation, intended use, and required qualifications for personnel.
Outlines applicable standards and European directives for conformity.
Emphasizes observing instructions and device symbols for safe operation and maintaining factory condition.
Details warnings and precautions for operation in hazardous areas, including explosion protection.
Covers general safety for assembly, installation, and hazardous area considerations.
Specifies requirements for environment, mounting, and vibrations.
Details cable connection and gas requirements for CSA and FM certification.
Covers laws, directives, and safety precautions for electrical connections.
Illustrates pipe connections for specific analyzer models.
Provides guidance on power supply, signal cables, and terminal connections.
Details gas connections, materials, and sample gas preparation.
Explains connecting analyzers for hazardous areas, including flame arrestors and electricals.
Emphasizes safety measures for commissioning, including hazardous voltages and error handling.
Covers precautions for commissioning in hazardous areas, including explosion risks.
Describes test setups and procedures for leak testing the containment system.
Details Ex px safety equipment, pressure, and key switch functions for hazardous areas.
Highlights safety precautions for working on the device, including hazardous voltage and media.
Outlines specific requirements for analyzers and Ex px safety equipment maintenance in hazardous areas.
Lists available spare parts for analyzers used in hazardous areas.
Lists general technical data for all analyzers, including enclosure, electrical, and climatic conditions.
Provides detailed technical specifications for individual analyzer models.
Details explosion protection data, temperature classes, and groups for hazardous areas.
Covers sample gas inlet conditions, protective gas pneumatic data, and differential pressure monitoring.
Instructs on proper disposal of the analyzer as electronic waste, not with household waste.
Provides information on obtaining technical support and finding regional representatives.
Defines abbreviations and symbols used throughout the manual.