ULTRAMAT 6, OXYMAT 6, CALOMAT 6, ULTRAMAT 23,
OXYMAT 61
Schnittstelle / Interface PROFIBUS DP / PA
Beschreibung / Description 02 / 2002
s
A5E00054148-03
Function Block
Digital Output
PROFIBUS – DP / PA
Physical Block
Device Management
Diagnosis
cyclic
acyclic
AUTOCAL
SIMATIC PDM
CFC-diagnosis-tool PCS 7
Start / Abort
AUTOCAL +Status
Function Block
Analog Input 1
Function Block
Analog Input 2
A
larm
Warning
Scale...
Function Block
Analog Input 3
Value 1 + Status
Value 2 + Status
Value 3 + Status
A
larm
Warning
Scale...
A
larm
Warning
Scale...
signal 1
Transducer
-Block
Sensor 1
signal 3
Transducer
-Block
Sensor 3
signal 2
Detekto
r
1
Detekto
r
2
Detekto
r
3
Transducer
-Block
Sensor 2
Function Block
Analog Input 4
Value 4 + Status
A
larm
Warning
Scale...
signal 4
Transducer
-Block
Sensor 4
Detekto
r
4

Table of Contents

Other manuals for Siemens ULTRAMAT 6

Question and Answer IconNeed help?

Do you have a question about the Siemens ULTRAMAT 6 and is the answer not in the manual?

Siemens ULTRAMAT 6 Specifications

General IconGeneral
DisplayLCD with backlight
Measurement PrincipleNon-dispersive infrared (NDIR)
Gas ComponentsCO, CO2, NO, SO2, CH4
OutputAnalog (4-20 mA) and digital interfaces
Power Supply100 to 240 V AC, 50/60 Hz
Measurement RangeDepends on gas component (e.g., CO: 0-100 ppm to 0-100%)

Summary

Information for the User

Safety Notes

Provides essential safety guidelines and warnings for operation.

PROFIBUS Properties

PROFIBUS-PA

Details the PROFIBUS-PA communication protocol and its features.

Assembly Information

PROFIBUS-PA Bus Connectors

Pin Assignment PROFIBUS-PA Bus Connector

Details the pin configuration for PROFIBUS-PA connectors.

PROFIBUS-DP Bus Connectors

Pin Assignment of PROFIBUS-DP Bus Connector

Details the pin configuration for PROFIBUS-DP connectors.

Installing the Optional Module (Retrofitting)

Analog Input Block with ULTRAMAT, OXYMAT and CALOMAT

Discrete Output Block with ULTRAMAT, OXYMAT and CALOMAT

Physical Block with ULTRAMAT, OXYMAT and CALOMAT

Faults of ULTRAMAT / OXYMAT / CALOMAT

Maintenance requests of ULTRAMAT / OXYMAT / CALOMAT

Commissioning

Selection of the Nominal Configuration

PROFIBUS Address

Function Blocks

SIMATIC PDM Instrument Catalog

Starting SIMATIC PDM

Settings

Adapting to the Desired Process Variable

Warning and Alarm Limits

Failure Behavior

Status and Error Messages

Resetting

Operation

Setting the Station Address ULTRAMAT 6/OXYMAT 6/CALOMAT 6/ OXYMAT 61

Details how to set the PROFIBUS station address for specific devices.

Setting the Station Address ULTRAMAT 23

Firmware

Diagnostic Information

Function Block Al 1

Function Block TB 1

Physical Block PB

Function Block Al 2

Transducer Block TB 2

Function Block Al 3

Transducer Block TB 3

Function Block Al 4

Transducer Block TB 4

Function Block DO

Related product manuals