Siemens FIDAMAT 6 Specifications

General IconGeneral
Protection ClassIP54
Measuring ComponentsHydrocarbons
TechnologyFlame Ionization Detector (FID)
Applicationsprocess control
Measurement PrincipleFlame ionization
Measuring Range0 to 10, 000 ppm
Response Time< 1 s (T90)
Operating Temperature5 to 45 °C
Power Supply100 ... 240 V AC, 50/60 Hz
Output Signal4 to 20 mA, RS485

Summary

Safety instructions

Requirements for safe use

Emphasizes observing manual instructions and device symbols for safe operation and maintaining device condition.

Basic safety instructions

Covers critical warnings like danger of explosion from combustible gases and device modification risks.

Description

Method of operation

Explains the FID measuring principle, ion formation, current conversion, and substance class specificity.

Installing

Safety information for installation

Highlights warnings related to sample gas contact, combustible gases, and improper installation procedures.

Connecting

Safety information for connecting

Covers crucial safety aspects like hazardous voltage, missing ground terminals, and handling toxic/flammable gases.

Commissioning

Safety information and preparation

Covers safety warnings for commissioning, device position, operation, interfaces, and gas preparation.

Commissioning and operation procedures

Outlines procedures for commissioning, including warm-up phases, operating states, and state changes due to faults.

Measuring ranges

Explains setting measuring ranges, spans, zero points, calibration methods, and AUTOCAL functions.

Operation

User interface and operating modes

Details the device's operating modes (Coded, Decoded, Operator control), operator keys, and input editing.

Calibration procedures

Covers general calibration information, zero point, span calibration, setpoints, and AUTOCAL functions.

Functions

Calibration functions

Explains calibration submenu options including zero calibration, span calibration, and AUTOCAL.

Configuration options

Details configuration settings like analog output, relay assignments, binary inputs, ELAN, and PROFIBUS.

Service and maintenance

General safety information

Covers critical safety warnings about dangerous voltage, gas lines under pressure, and faulty adjustments.

Spare parts and accessories

Technical specifications

General technical data of FIDAMAT 6 analyzers

Covers design, enclosure, electrical characteristics, fuse values, and gas consumption data for FIDAMAT 6 analyzers.

Technical specifications of the FIDAMAT 6-E

Lists general specs, gas inlet conditions, time response, measuring characteristics, and electrical I/O for FIDAMAT 6-E.

Technical data of the FIDAMAT 6-G

Details general specifications, gas inlet conditions, and pressure/flow data for the FIDAMAT 6-G.

Appendix

Overview of operating functions

Lists device functions categorized by submenu, corresponding to software version V1.3.6.