PRODUCT INSTRUCTION MANUAL V1.0
MAY 2016
SITRANS STANDARD LIQUID ULTRASOINC FLOW METER
MODELS: FUS1010

Table of Contents

Questions and Answers:

Siemens FUS1010 Specifications

General IconGeneral
BrandSiemens
ModelFUS1010
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction

Preface

Provides information for using the device, aimed at installers, engineers, and maintenance personnel.

Items supplied

Lists the components included with the SITRANS F transmitter.

Inspection

Instructions for checking mechanical damage and scope of delivery against ordering information.

History

Details the revisions and changes made in different editions of the operating instructions.

Further Information

Provides information on accessing product details on the Internet and worldwide contacts.

Safety notes

General safety instructions

Outlines basic safety requirements for proper operation and maintenance of the instrument.

Warning Symbols

Explains the meaning of various warning symbols used in the manual.

Laws and directives

Covers general requirements for equipment installation compliance with national regulations.

Lithium batteries

Details safety precautions for handling and using lithium batteries due to potential hazards.

Installation in hazardous area

Provides warnings and requirements for installing equipment in hazardous areas, including approvals.

Safety Notes

Safety information for hazardous areas, including requirements for unqualified personnel and proper installation.

Certificates

Information on where to find certificates for the device, including online resources.

Description

FUS1010 features

Highlights the SITRANS FUS1010's accurate flow measurement using WideBeam technology and multi-parameter delivery.

NEMA 4X and NEMA 7 Transmitters

Describes SITRANS FUS1010 NEMA transmitter labels and model numbers.

Applications

Explains SITRANS F flow meters for measuring liquids and gases, and lists typical applications.

Theory of Operation

Explains the MultiPulse transit-time technology, sensor operation, and signal processing.

Flow Meter Types

Introduces available flow meter types like 2-Channel, 4-Channel, 2-Path, and 4-Path.

Installing/mounting

Installation safety precautions

Warns about high pressure hazards during sensor mounting and recommends special precautions.

Determining a location

Provides guidance on selecting sensor locations considering upstream/downstream conditions and pipe system characteristics.

Use according to specifications

Covers essential requirements and prohibitions for using the flow meter as specified.

Application Guidelines

Outlines basic requirements for selecting mounting locations and pipe conditions for optimal operation.

Mounting the Transmitter

Details procedures for mounting the transmitter on a wall or pipe, including safety warnings.

Connecting

Safety notes for connecting

Provides critical safety information regarding electrical connections and hazardous locations.

Transmitter Wiring

Details wiring connections for the input power plug (J10) and cable management.

Wiring Temperature Sensor to Transmitter

Provides instructions for connecting temperature sensors to the analog input module, with safety warnings.

Navigating the Menu

Explains the multi-level structure of the Installation Menu for navigation.

Programming the Transmitter

Guides on selecting language, units, and meter type for transmitter configuration.

Sensor Installation

Covers Reflect and Direct Sensor Mounting modes and sensor identification notes.

Mounting Temperature Sensors

Explains the use of temperature sensors for normalizing sonic velocity and lists available sensor types.

Sensor Wiring

Provides instructions for connecting clamp-on and insert sensors to the transmitter, including safety warnings.

Commissioning

General requirements

Lists checks required before commissioning, including installation and hazardous location compliance.

Commissioning

Guides the user through the commissioning process, referring to transmitter programming and sensor installation.

Empty Pipe Set

Explains the Empty Pipe Set routine for alarm setting and available commands (MTYmatic, Actual MTY).

Installation Menus

Introduces the FUS1010 Installation Menu chart and navigation using arrow keys.

Functions

UniMass Table

Introduces UniMass feature for mass metering and flow profile compensation using temperature and sonic velocity.

Selecting Flow Units

Guides on selecting volumetric or mass flow units and associated time bases.

Zero Flow Adjust Menu

Explains zero flow compensation methods: AutoZero, Actual Zero, and ReversaMatic.

Span Data

Explains setting 0% and 100% output limits for volumetric flow, absolute flow, and sonic velocity.

Analog Out Setup

Details assigning data functions to analog outputs (current, voltage, pulse-rate).

Analog Input Setup

Guides on assigning active analog inputs and spanning them for variables like viscosity or specific gravity.

Expanded I/O Option

Introduces the Expanded I/O Module for additional analog outputs and its compatibility.

Logger Control

Covers the Logger Control menu for selecting data items, logging intervals, and destinations.

Operation Adjust Menu Settings

Guides on using Operation Adjust menu for fine-tuning meter characteristics, including damping controls.

Setting Relays

Explains assigning functions to channel relays (Alarm and Pulse) and lists available relay options.

Memory Control

Provides an overview of the Memory Control menu for viewing memory status and managing data.

Analog Output Trim

Details the Analog Output Trim function for fine-tuning analog outputs using an ammeter or frequency counter.

Resistive Temperature Device (RTD) Calibration

Explains calibrating temperature sensors to an external standard via data entry or ice-bath procedure.

Reflexor

Introduces the Reflexor operating mode, its principles, typical installation steps, and sensor selection.

Alarm, error, and system messages

Alarm Codes

Lists alarm codes that appear on the flow meter display and in datalogger status messages.

Service and maintenance

Maintenance

Discusses the maintenance-free nature of the device and recommends periodic inspections.

Technical support

Provides contact information for technical questions via Internet and phone.

Return procedures

Outlines the required forms and procedures for returning devices for service or repair.

Battery disposal

Explains battery disposal regulations and Siemens' acceptance of waste industrial batteries.

Disposal

Provides guidance on disposing of electronic equipment according to WEEE directive and local regulations.

Troubleshooting

Troubleshooting

Lists common error messages, probable causes, and recommended solutions for troubleshooting.

F4 Reset Procedure

Details the F4 reset sequence for restoring operation, including clearing active and all saved memory.

Test Facilities Graph Screen

Introduces the Test Facilities Graph Screen as a diagnostic tool for troubleshooting and signal analysis.

Site Setup Data

Explains the Site Setup Data menu for sensor characteristics and operation, including parameters for technical interpretation.

Force Transmit

Introduces the Force Transmit diagnostic routine for searching amplitude levels and setting conditions.

Technical data

Technical Data

Provides technical specifications for the transmitter, degree of protection, input ranges, and accuracy.

Appendix

Ordering

Provides information on obtaining the latest ordering data from the Siemens catalog online.

I/O Connections and Wiring

Details terminal block wiring for various I/O modules and expanded I/O modules.

RS-232 Connection

Explains hardware and software requirements for PC connection via RS-232 serial port.

Flowrate Calibration and Calibration Tables

Explains flowrate calibration methods: Intrinsic, Kc, and Calibration Tables.

Setup Procedure for Wet-Flow Calibration

Provides instructions for wet-flow calibration, emphasizing data corruption warnings.

Appendix B

Installation/Outline Drawings

Lists installation and outline drawings for the SITRANS FUS1010 NEMA 4X flow meter.

Related product manuals