SITRANS F
Ultrasonic Flowmeters
SITRANS FS130 & FS230
Compact Operating Instructions
7ME372 (HART/Modbus)
12/2023
A5E38755607-AF
Introduction
1
Safety notes
2
Installing/mounting
3
Connecting
4
Commissioning
5
Service and maintenance
6
Technical speci󹪝cations
7
Dimension drawings
8
Product documentation
and support
A

Table of Contents

Other manuals for Siemens SITRANS FS230

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS FS230 and is the answer not in the manual?

Siemens SITRANS FS230 Specifications

General IconGeneral
Housing MaterialAluminum or stainless steel
Accuracy±1% of reading
Repeatability±0.2% of measured value
Temperature Range-40 to +150 °C
Pipe Size RangeDN15 to DN300
Output Signal4 ... 20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply24 V DC
DisplayLCD with backlight

Summary

Safety notes

Warning symbols on the device

Explains the meaning and importance of symbols displayed on the device.

Use in hazardous areas

Critical safety information for operating the device in hazardous environments.

Hazardous area approvals

Lists specific approvals and conditions for use in hazardous areas.

Installing/mounting

Basic safety notes

General safety precautions for installation and mounting procedures.

Wall mount enclosure specific conditions of use

Specific conditions and safety notes for wall mount enclosures.

Industrial enclosure specific conditions of use

Specific conditions and safety notes for industrial enclosures.

External DSL specific conditions of use

Safety conditions for external DSL connections, including spark risks.

Installation Instructions

Detailed procedures for installing the device and its components.

Industrial enclosure installation

Specific installation steps for devices in industrial enclosures.

Mounting the transmitter

Steps for mounting the transmitter onto a bracket.

Wall mount enclosure installation

Instructions for installing devices in wall mount enclosures.

Mounting the external DSL

Procedures for mounting the external DSL unit.

Connecting

Connecting the sensor cables (internal DSL only)

Step-by-step guide to connecting sensor cables for internal DSL systems.

Connecting the sensor cables to the sensor

Instructions for connecting sensor cables to the sensor itself.

Connecting the external DSL

Procedures for connecting the external DSL unit.

Connecting the sensor cables

Steps for connecting sensor cables to the external DSL.

Connecting industrial enclosure

Procedures for connecting devices within an industrial enclosure.

Connecting Modbus

Steps for establishing Modbus communication.

Connecting the power supply

Procedures for connecting the device's power supply.

Connecting wall mount enclosure

Procedures for connecting devices within wall mount enclosures.

Connecting the sensor cables (internal DSL only)

Steps for connecting sensor cables for internal DSL in wall mount enclosures.

Connecting Modbus (wall mount)

Steps for establishing Modbus communication in wall mount transmitters.

Connecting HART

Steps for establishing HART communication in wall mount transmitters.

Connecting the power supply (wall mount)

Procedures for connecting the power supply for wall mount devices.

Commissioning

Basic Safety Notes

Critical safety warnings and precautions for commissioning procedures.

Service and maintenance

Basic safety notes

Essential safety precautions for service and maintenance activities.

Maintenance and repair work

Guidelines and warnings for performing maintenance and repair.

Technical specifications

Related product manuals