4.7.4 Connecting Modbus (wall mount)
Procedure
1. Open enclosure lid.
2. Remove blind plug and 󹪝t cable gland.
3. Push cable through open gland and cable path.
4. Restore ferrule and tighten cap to hold cable in place.
5. Connect wires to terminals using wiring tool.
Note
The terminal connector is detachable
For easier access unplug the terminal connector. After connecting the wires, plug the
terminal connector back in.
Wall mount transmitter




Modbus
B
A
6. Tighten cable gland.
Connecting
4.7Connecting wall mount enclosure
SITRANS FS130 & FS230
Compact Operating Instructions, 12/2023, A5E38755607-AF 73