Loading...
Figure3-8 Mounting DSL to mount bracket
3.7 Installing sensors in Re󹪞ect mount
Re󹪞ect mount - Sensor installation using mounting frames and spacer bar
1. Use the Sensor settings Wizard setup procedure to program the meter for application
parameters such as pipe size, liquid type, and sensor size. Once entered the transmitter will
return a spacing index number appropriate for the application.
2. Using the supplied space bar, set the distance between the sensors according to the spacing
index number provided by transmitter. The spacing index provides the correct distance
between the sensors based on the pipe size given.
Before continuing refer to the Re󹪞ect mount installation diagram example below.
Installing/mounting
3.7Installing sensors in Re󹪞ect mount
SITRANS FS130 & FS230
32 Compact Operating Instructions, 12/2023, A5E38755607-AF