EasyManua.ls Logo

Siemens LDS 6 User Manual

Siemens LDS 6
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A5E00295894D-05 GN: 30500_LDS6
LDS 6 In-situ Laser Gas Analyzer
Operating Instructions 01/2009
LDS 6
In-situ Laser Gas Analyzer
Operating Instructions
01/2009
www.siemens.com/processautomation
Änderungen vorbehalten
A5E00295894-05
© Siemens AG 2009
Siemens AG
Industry Automation (IA)
Sensors and Communication
Process Analytics
76181 KARLSRUHE
DEUTSCHLAND
Continuous Gas Analysis
A5E00295894
4 019169 134279
A5E00295894

Table of Contents

Other manuals for Siemens LDS 6

Question and Answer IconNeed help?

Do you have a question about the Siemens LDS 6 and is the answer not in the manual?

Siemens LDS 6 Specifications

General IconGeneral
BrandSiemens
ModelLDS 6
CategoryMeasuring Instruments
LanguageEnglish

Summary

Technical Information

2.1 General Description

Introduces the LDS 6 as a diode laser gas analyzer for fast, non-contact measurement.

2.3 Operating Principle

Explains the single-line molecular absorption spectroscopy method used by the LDS 6.

2.5 Measurement Principle

Details the Beer-Lambert law application and influences like dust, temperature, pressure.

Installation Guidelines

3.1 Safety Information

Covers electrical, laser, heat, pressure, and explosion protection safety measures.

3.3 Electrical Connections

Details power supply, hybrid, and signal cable connections for the LDS 6.

Operation

4.2 Input Sequence of Data

Outlines the steps for interacting with the LDS 6 via its menu and keypad.

4.3 Analyzer Functions

Summarizes analyzer functions by type: analyzer-specific, channel-specific, component-specific.

Alarms

5.1 Alarm Response

Describes the five types of alarms and how they are signaled in the status row and logbook.

5.2 Maintenance Request Alarm

Lists messages signaling a need for maintenance and their possible causes/actions.

5.3 Faults Alarm

Details fault alarms that prevent measurement, their causes, and required actions.

Maintenance and Service

6.3 Cleaning the Wedge Windows

Details how to clean wedge windows, emphasizing safety precautions with steam purging.

Technical Data

8.1 Central Unit

Details analytical performance, general specs, design, electrical characteristics, and climatic conditions.

Dimensional Drawings

ESD guidelines

A.1 ESD guidelines

Explains ESD, its sensitivity, and basic protective measures like grounding.