Siemens 6 Series User Manual

Siemens 6 Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Siemens AG 2018. All rights reserved
A5E45779144002-01, 09/2018
1
Continuous gas analysis
19" rack units of Series 6 and ULTRAMAT 23
Compact Operating Instructions in accordance with EN
61010-1 and EN 60079-0
Compact Operating Instructions
1
Introduction
1.1
Purpose of this documentation
These instructions are a brief summary of important features, functions and safety information, and contain all necessary
information required for safe use of the respective devices. Read the manual carefully prior to assembly and startup! To
ensure correct handling, become acquainted with the principle of operation of the respective device.
The instructions are aimed at persons who mechanically assemble the devices, connect them electrically, and commission
them.
To achieve optimum usage of the respective device read the detailed version of the respective operating instructions.
1.2
Product versions
These instructions are valid for the 19" rack units of Series 6 and the ULTRAMAT 23 gas analyzers which are available as
19" rack unit as well as bench-top unit. This includes the devices listed below:
ULTRAMAT 23
ULTRAMAT 6E
ULTRAMAT/OXYMAT 6E
OXYMAT 6E
OXYMAT 61
OXYMAT 64
CALOMAT 6E
CALOMAT 62E
FIDAMAT 6
These gas analyzers are suitable for a wide variety of measurements and are also available in different versions. The data
on the label, among others, indicates which device version you have.
Question and Answer IconNeed help?

Do you have a question about the Siemens 6 Series and is the answer not in the manual?

Siemens 6 Series Specifications

General IconGeneral
CategoryMeasuring Instruments
ManufacturerSiemens
Series6 Series
Process temperatureDepends on model
Process pressureDepends on model
AccuracyDepends on model
Output4 to 20 mA
CommunicationHART
Power supply24 V DC
Enclosure ratingIP67
MaterialStainless steel, Plastic
ResolutionDepends on model
DisplayLCD
Operating Temperature-20°C to +60°C
Storage Temperature-40°C
DimensionsDepends on model
WeightVaries depending on model

Summary

1.3 General Information and Personnel

1.6 Qualified Personnel

Defines the qualifications required for personnel handling the device.

2 Safety Instructions

2.1 Prerequisites for safe use

Essential conditions for safe operation and handling of the device.

2.2 Analyzers in Hazardous Areas

2.2.1 CALOMAT 6E

Specific safety information for the CALOMAT 6E in hazardous areas.

2.2.2 ULTRAMAT 23

Specific safety information for the ULTRAMAT 23 in hazardous areas.

2.3 Analyzers in Biogas Plants

2.3 Analyzers in biogas plants

Safety considerations for analyzers used in biogas plants, focusing on H2S and methane.

3 Assembly/Installation

3.1 Safety information

General safety instructions for assembly and installation.

3.2 Installation Location Requirements

3.2 Installation location requirements

Guidelines for selecting an appropriate installation location for the device.

FM and CSA Guidelines

4 Connecting

4.1 Safety Instructions

General safety rules and specific precautions for connecting the device.

4.2 Electrical and Signal Connections

Covers power, signal lines, PROFIBUS DP, and pin assignments.

5 Commissioning

6 Service and Maintenance

6.1 Safety Instructions

General safety instructions for service and maintenance activities.

6.1.1 General Safety Instructions

Precautions for handling hot/toxic media and electrostatic discharge.

6.1.2 Analyzers in Hazardous Areas

Safety instructions for maintenance of analyzers in hazardous areas.