Loading...
en Cleaning and maintenance
28
5. Put the service flap back on, lock it
into place and close it.
Note: To prevent unused detergent
from flowing straight into the drain
during the next wash: Pour 1 litre of
water into left-hand compartment and
start the q Rinse/Spin 0 programme.
The drain hose at the siphon
is blocked
1. Switch off the appliance. Pull out the
mains plug.
2. Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
3. Clean the drain hose and siphon
connecting piece.
4. Re-attach the drain hose and secure
the connection point using the hose
clamp.
Filter in the water supply is
blocked
1. Release water pressure in the supply
hose:
a) Turn off the tap.
b) Select any programme (except
q Rinse/Spin 0).
c) Touch the I button. Allow the
programme to run for approx. 40
seconds.
d) Press the # button. The
appliance is switched off.
e) Pull out the mains plug.
2. Clean the filters:
a) Disconnect the hose from the
tap.
Clean the filter with a small brush.
b) For standard and Aqua-Secure
models, clean the filter on the
rear of the appliance:
Disconnect the hose from the
rear of the appliance.
Use pliers to remove the filter and
then clean it.
3. Connect the hose and check for
leaks.