Set electricity rate 1 and 2
Note: the price per kWh is set to 0 on delivery.
Note: you can set two different electricity rates (e.g. daytime
and night-time rate) for the power cost meter. In order to use
this function, you must set the starting times for electricity rate
1 and 2.
IMPORTANT! Electricity rate 1 is automatically the rate
that was programmed first.
Tip! You can obtain details of the current price per kWh
from your electricity provider.
Note: please make sure that the top third of the LC display
1
shows the standard display (see “Display current”).
Proceed as follows:
1. Press the “DOWN” button
4
until the price per kWh
symbol
19
(“PRICE KWh”) appears in the centre of the
LC display
1
.
2. Press the “UP” button
5
so that four digits appear in the
bottom third of the LC display
1
. The symbol
15
also appears.
3. Now press the “SET” button
2
. The first digit starts to
flash.
4. Press the “UP”
5
or “DOWN” button
4
to set the
units digit before the decimal point of the current price