8
AL 05
Request assistance from qualified
technical personnel.
AL 06 (fig. 6)
Press the key of the controls to
re-start the boiler.
If the error persists, request assi-
stance from qualified technical
personnel.
AL 07 (fig. 7)
Press the key of the controls to
re-start the boiler.
If the error persists, request assi-
stance from qualified technical
personnel.
AL 08
Request assistance from qualified
technical personnel.
AL 10
Request assistance from qualified
technical personnel.
AL 13 (fig. 8)
Press the key of the controls to
re-start the boiler.
If the error persists, request assi-
stance from qualified technical
personnel.
AL 14
Request assistance from qualified
technical personnel.
AL 15
Request assistance from qualified
technical personnel.
AL 18
Request assistance from qualified
technical personnel.
1.5 MINIMUM CLEARANCES
The following MINIMUM CLEARANCES
must be available for servicing the
appliance:
1.6 ROUTINE SERVICING
To comply with the conditions of any
extended warranty offered and to
ensure continued safe and efficient
operation, the boiler must be serviced
at regular intervals, at least once a
year.
This service must be recorded in the
Benchmark section of this manual.
It is the law that any service work
must be carried out by a Gas Safe
Register registered engineer.
1.7 ELECTRICAL SUPPLY
THIS APPLIANCE MUST BE EARTH-
ED. The mains supply must be fused
at 3 amp.
1.8 VENTILATION
If the appliance is installed in a cabinet,
the latter MUST NOT be used for stor-
age purposes. Any ventilation provided
for the appliance during installation
MUST NOT be blocked and a periodic
check must be made to ensure that
the vents are free from obstructions.
1.9 CLEANING
Use only a damp cloth and mild deter-
gent to clean the appliance outer cas-
ing. DO NOT use abrasive cleaners.
1.10 SAFETY
It is essential that the instructions in
this booklet are strictly followed for
the safe and economical operation of
this appliance.
The appliance functions as a fan
assisted balanced flue unit. The flue
terminal MUST NOT BE OBSTRUCTED
under any circumstances. If damaged,
turn off the appliance and consult the
installer, service engineer, or gas sup-
plier. If it is known or suspected that a
fault exists on the appliance it MUST
NOT be used until the fault has been
rectified by a competent person.
WARNING:
IF A GAS LEAK IS SUSPECTED OR
EXISTS, TURN OFF THE GAS SUPPLY
TO THE APPLIANCE AT THE GAS
SERVICE COCK.
DO NOT OPERATE ANY ELECTRICAL
SWITCHES.
DO NOT OPERATE ANY ELECTRICAL
APPLIANCE.
OPEN ALL WINDOWS AND DOORS.
DO NOT SMOKE.
EXTINGUISH ALL NAKED LIGHTS.
CONTACT THE NATIONAL GAS
EMERGENCY SERVICE IMMEDIAT-
LEY ON 0800111999.
1.11 INSTRUCTIONS FOR
OPTIONAL TIMER SIME PART
NUMBER 7102604 / BCG
NUMBER 138493 (fig. 10)
Normal Time Mode
The display shows the room tempera-
ture. If the batteries are low the
will be flashing. The old batteries must
be replaced.
The anti freeze function is activated
with on the display when the tem-
perature detected is 5°C or below.
Fig. 7
Fig. 8
Fig. 6
For servicing
ABOVE THE
APPLIANCE CASING
300 mm
AT THE R.H.S. 15 m m
AT THE L.H.S. 15 m m
BELOW THE
APPLIANCE CASING
200 mm
IN FRONT OF THE
APPLIANCE
500 mm

Other manuals for Sime FORMAT DGT HE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sime FORMAT DGT HE and is the answer not in the manual?

Sime FORMAT DGT HE Specifications

General IconGeneral
BrandSime
ModelFORMAT DGT HE
CategoryBoiler
LanguageEnglish

Related product manuals