13 ANNEX AA.1
Information requirements for boiler space heaters, boiler combination heaters
Model(s):
Condensing boiler: Yes
Low-temperature boiler: Yes
B11 boiler: No
Cogeneration space heater: No Equipped with a supplementary heater: No
Combination heater: Yes
Item Symbol Value Unit Item Symbol Value Unit
Nominal heat output for space heating
P
n
24 kW
Seasonal space heating energy efficiency
ηs 93 %
For boiler space heaters and boiler combination heaters:
useful heat output
For boiler space heaters and boiler combination heaters:
useful efficiency
At nominal heat output and high-
temperature regime
a
P
4
23,6 kW
At nominal heat output and high-
temperature regime (*)
η4 87,9 %
At 30% of nominal heat output and
low-temperature regime
b
P
1
7,8 kW
At 30% of nominal heat output and
low-temperature regime (*)
η1 97,7 %
Auxiliary electricity consumption Other items
At full load el
max
0,043 kW Standby heat loss Pstby 0,082 kW
At part load el
min
0,012 kW Ignition burner power consumption Pign 0 kW
In standby mode PSB 0,004 kW Emissions of nitrogen oxides NOx 37 mg/kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
ηwh 86 %
Daily electricity consumption Qelec 0,123 kWh Daily fuel consumption
Qfuel
22,555 kWh
Contact details Fonderie Sime S.p.A. Via Garbo 27, 37045 Legnago (VR) ITALIA
a. High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
b. Low-temperature regime means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return
temperature.
(*) The yield data have been calculated using the higher heating value.