Page 39
In the event of the AP14H failing, the LED located under the terminal bay cover of the SCP12 Course
Computer can be used to identify the potential source of the problem -
Flashes Diagnosis Fault Location
2 Invalid rudder feedback reading from SLF12 SLF12
4 Current limit exceeded SRP12, SCP12
5 Control unit not connected SHC14
6 No compass data received SHS12
7 No compass/controls detected SHC14, SHS12, SCP12
8 Rudder limits not set / calibration failed SLF12, SCP12
In the event of the AP14R failing, the LED located on the circuit board under the black cover of the
SRD12 Drive Unit can be used to identify the potential source of the problem -
Flashes Diagnosis Fault Location
5 Control unit not connected SHC14
6 No compass data received SHS12
7 No compass/controls detected SHC14, SHS12, SRD12
8 Compass calibration failed SRD12
Page 38
7.5 Optional Accessories
The following optional accessories for the
AP14H and AP14R are available from your
Simrad dealer. Please quote the correct part
number when ordering.
SCJ12
Additional Control
Unit +
Junction Box
SCJ14
Hand Controller +
Junction Box
LFK500
SLF12 Feedback Mounting Accessory Kit -
balljoint & universal joint mounting foot.
(for AP14H hydraulic drive option only)
LFKSeastar
Kit for mounting SLF12 (AP14H only) to
Teleflex HC5345 cylinders