Transducer connection
Warning: Removing the transducer cables from the S5100 while the
module is powered on can cause sparks that can damage the S5100
transmitter as well as the transducers. Remove the transducer cables only
after the module has been disconnected from its power source.
Transducers with 9 pin connector
Up to three 9 pin transducers can be connected directly to any of the sonar channels on the
S5100.
One 9 pin transcuder can be connected to the remaining open channel after a dual
connector transducer has been attached.
Transducers with 7 pin connector
Transducers with a blue 7 pin connector must be connected to S5100 by using the 7-9
adapter cable. 3 of these adapter cables are included in the box.
The adapter cable connects to any of the sonar channels.
Transducers with bare wires
Transducers with bare wires must be connected to the S5100 via the optional Junction box
(A) (part number 000-13262-001).
The Junction box cable connects to the sonar channels as follows:
• single frequency transducers: to any of the sonar channels
• dual frequency transducers: to Channel-1 and Channel-2, or to Channel-2 and Channel-3
as described in "Transducers with two connectors" on page 13
Detailed installation description and wiring diagram is included with the junction box.
12
Wiring | S5100 Installation Manual