EasyManua.ls Logo

Simu T5EHz - End Limit Re-adjustment; UP End Limit Re-adjustment (B & D); DOWN End Limit Re-adjustment (C & D); Programming Control Points

Simu T5EHz
40 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
>>
2
PROG < 1s.
>>
1
PROG ≥ 3s.
6.2- Conrm the operation from the new transmitter you want to
program:
- Press the PROG key of the transmitter for 1 second. The motor will run
for 0,5 second in one direction and then in the other.
6.1- Open the memory of the receiver from the control transmitter:
- Press the PROG key of the transmitter for about 3 seconds. The motor
will run for 0,5 second in one direction and then in the other.
Programming a new (individual, group or general) control point
6
- For group controls, repeat operations 6.1 and 6.2 for each motor in the group.
- For general controls, repeat operations 6.1 and 6.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 6.1 with a programmed transmitter, then per-
form the operation 6.2 with the transmitter to be deleted.
Recording / controling / deleting intermediate position
7
5s
Recording:
- Move the motor to the wanted
position.
- Press 5 seconds on the "stop" key.
The motor will run for 0,5 second in
one direction and then in the other.
0,5s
Control:
- Press the "stop" key for 0,5
second. The motor runs to
the intermediate position.
Deleting :
- Position the motor on the intermediate position. Press 5 seconds on the Stop key, the intermediate position is deleted.
Re-adjustment of end limits and modication of the rotation direction (in user mode)
8
5s
3
21 4
2s
3
412
5s
2s
8.1- Re-adjustment of UP end limit (mounting B and D only):
8.2- Re-adjustment of DOWN end limit (mounting C and D only):
1- Move the motor to the UP end limit previously adjusted in §4.3 with the UP key.
2- Press simultaneously for 5 seconds the UP and DOWN keys. The motor will run for 0,5 second in one direction and
then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Conrm the new position by pressing 2 seconds the STOP key. The motor will run for 0,5 second in one direction and
then in the other direction. The new end limit is memorized.
1- Move the motor to the DOWN end limit previously adjusted in §4.3 with the DOWN key.
2- Press simultaneously for 5 seconds the UP and DOWN keys, The motor will run for 0,5 second in one direction and
then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Conrm the new position by pressing 2 seconds the STOP key. The motor will run for 0,5 second in one direction and
then in the other direction. The new end limit is memorized.
4/5
The re-adjustment of end limits is automatic every 60 cycles (during 4 cycles) or after a power supply failure
for the following installation U
P end limit, mounting A and C,
DOWN
end limit, mounting A and B.