(Auto
m
at
ic)
”.
 If 
“AUTO” is 
selected, the ventilator 
operates at 
temperature  differences  larger  than 
9 
degrees  at  top speed. 
I
f
 the temperature  reduces to 
a 
d
i
fferenc
e
 smaller than 4 degrees,  the ventilator 
switches 
to middle blower 
position. 
If the temperature  reduces  further 
until 
the target  temperature,  
the 
ventilator 
switches 
to the lowest blower 
posit
i
on.
 
 
7.
 
TI
MER
 
Programmable timer button for 
delayed 
start up or 
delayed 
shutdown 
 
How 
to 
pr
og
r
a
m
 a delayed 
s
t
a
r
t
 up 
This function  
is used to set the number of 
hours 
delay before  the 
appliance 
comes on. Proceed  as 
follows
:
 
  Press 
[TIMER]  
button in 
Stand-by 
mode 
(unit 
is 
p
l
ugg
e
d
 in but  not in operation,  no 
disp
l
a
y
 on 
the
 
panel), to set the number of 
hours 
delay before  the 
appliance 
comes on. 
  Select the 
r
e
qu
i
r
ed
 
function (cooling, 
heating, and 
d
e
humid
ific
a
t
ion),
 wait 
until 
the 
unit 
displays 
the 
ambient temperature,  and  then set the desired 
temperature.
 
  After the set number of 
hours 
has expired,  the 
unit 
starts 
a
u
t
oma
tic
ally
.
 
 
If you press  the 
[POWER]   
button before  the time has expired,  the 
delayed 
start up 
will 
be 
c
a
nc
elled
, 
the
 
unit
 
turns 
on and 
c
a
n
 be 
operated 
in the  required  operating  
m
o
de
.
 
 
How 
to 
pr
og
r
a
m
 a delayed 
s
h
ut
d
o
w
n
 
This function  
is used to set the number of 
hours 
delay before  the 
appliance 
goes off. Proceed as 
fo
llows
:
 
 
  Start the 
unit 
in required 
function (cooling, 
heating or 
de
humidify
i
ng
)
 
  Press the 
[TIMER] 
button 
du
r
in
g
 
op
era
t
io
n
 and enter the required number of 
hours 
dela
y 
be
fore
 
the 
appliance 
goes off. 
   After the flashing of the number of 
hours 
on the 
LED 
has stopped,  can select the 
requir
ed 
temperature.
 
  After the set number of 
hours 
has expired,  the 
unit shuts 
down 
a
u
toma
tic
ally. 
 
If you press  the 
[POWER]  
button before  the 
time 
has expired,  the 
unit shuts 
down. 
 
8.
 
SLEEP
   
This function  
is 
i
d
e
al
 for the night 
a
s
 it 
gradually 
reduces operation  of the 
appliance. 
The 
sleep 
funct
i
on
 
maintains the  room at 
optimum 
temperature 
and 
with silent 
op
erat
ion.
 
When you use the sleep 
function, 
first set  the 
timer 
as 
des
c
r
i
bed
 in the functions. 
 
Delayed start and 
delayed 
shutdown: 
Press the 
[TIMER] 
button 
until 
the required 
hours 
appear 
on 
the 
d
i
sp
lay
.
 After the hour 
d
i
spla
y
,
 the display 
switches 
a
u
toma
tic
all
y
 to the previous set temperature  
d
i
sp
lay
. 
To 
change the temperature,  press the 
[TEMP+] 
or 
[TEMP-] 
buttons. With each  press  on the button, 
the
 