2.4 Cooling and Heating Data Sheet in Rated Frequency
2.5 Noise Curve
Indoor side noise when blowing Outdoor side noise when blowing
Indoor fan motor rotating speed
Compressor frequency(Hz)
Noise dB(A)
12K Cooling
09/12K Heating
12K
09K
18K
18K
24K
24K
Cooling:
Rated cooling
condition(°C) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
27/19 35/24
09K 0.8 ~ 1.1 12 to 15 65 to 38
TURBO High
49
12K 0.8 ~ 1.1 11 to 14 64 to 37 60
18K
0.9 ~ 1.1 12 to 14 75 to 37
52
24K 72
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Heating:
Rated cooling
condition(°C) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
20/- 7/6
09 2.8 ~ 3.2 35 to 63 2 to 5
TURBO High
59
12K 2.8 ~ 3.2 35 to 65 2 to 5 67
18K
2.2 ~ 2.4 70 to 35 2 to 4
65
24K 77