12
Service Manual
2.2 Operation Characteristic Curve
2.3 Capacity Variation Ratio According to Temperature
Heating operation ambient temperature range is -22ºC~24ºC
Heating operation ambient temperature range is -15ºC~24ºC
Cooling Heating
C u r r e n t ( A )
C u r r e n t ( A )
01020304050607090010 20 30 40 50 60 70 80 90 100 120110
80
11
10
9
8
7
6
5
4
3
2
1
0
Compressor speed (rps)
11
10
9
8
7
6
5
4
3
2
1
0
Compressor speed (rps)
220V
230V
240V
220V
230V
240V
Conditions
Indoor: DB27°C/WB19°C
Outdoor: DB35°C/WB24°C
Indoor air flow: High
Pipe length: 5m
Conditions
Indoor: DB20°C/WB15°C
Outdoor: DB7°C/WB6°C
Indoor air flow: High
Pipe length: 5m
Cooling Heating
Capacity ratio(%)
gnilooC
gnilooC
Outdoor temp.(°C)
Capacity ratio(%)
Outdoor temp.(°C)
gnitaeH
Capacity ratio(
%)
Outdoor temp.(°C)
gnitaeH
Capacity ratio(
%)
Outdoor temp.(°C)
0
20
40
60
80
100
120
140
-15-10 -5 0510 15 20 25 30 35 43
0
20
40
60
80
100
120
140
-15-10 -5 0510 15 20 25 30 35 43
0
20
40
60
80
100
120
140
-22 -15 -
10
-7 0 2 7 15 18 21 24
Conditions
Indoor:DB20°C
Indoor air flow:Super High
Pipe length:5m
0
20
40
60
80
100
120
140
-22 -15 -
10
-7 0 2 7 15 18 21 24
Conditions
Indoor:DB20°C
Indoor air flow:Super High
Pipe length:5m
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m
09/12K
18K
24K
09/12K
18K
24K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sinclair Focus Plus YAC1FB9 and is the answer not in the manual?

Sinclair Focus Plus YAC1FB9 Specifications

General IconGeneral
BrandSinclair
ModelFocus Plus YAC1FB9
CategoryAir Conditioner
LanguageEnglish

Related product manuals