SK160
Manuale di uso e manutenzione
Use and Maintenance manual
Manuel d’utilisation et de maintenance
Bedienungs- und Wartungsanleitungen
Manual de uso y mantenimiento
103660
REV02
09/2018

Table of Contents

Questions and Answers

  • G
    Glenn JonesAug 9, 2025
    What to do if my Sincro Inverter has no voltage?
    • B
      Bradley MorrisAug 9, 2025
      If your Sincro Inverter shows no voltage, several issues could be the cause. First, check all connections to ensure they are secure. A faulty AVR could be the problem; check the fuse and consider replacing the AVR. Also, inspect the rectifier bridge. An open stator exciter circuit or a main winding fault could also be responsible; check the stator/rotor windings resistances and insulation. In some cases, the machine may be demagnetized; excite the alternator by applying a 6-12 voltage across the exciter terminals for a second, respecting the polarities while the engine is running.
  • R
    robinsontammyAug 16, 2025
    Why is my Sincro SK160 SA1 voltage so low?
    • R
      Robert HansonAug 16, 2025
      If your Sincro Inverter is showing low voltage, try these steps: * Adjust the voltage using the potentiometer «V» on the AVR to set the reference voltage to the desired value. * Check and adjust the under-frequency protection value for the nominal frequency (50Hz or 60Hz). * Verify the engine speed to ensure it is correct, as a low engine speed can cause low voltage. * If these steps don't work, the AVR may be faulty and need replacement.
  • W
    William GibsonAug 25, 2025
    What causes high voltage in a Sincro Inverter?
    • R
      Robin CrawfordAug 25, 2025
      If your Sincro Inverter is producing high voltage, the issue may stem from several causes. Begin by adjusting the voltage with the potentiometer «V» on the AVR to ensure the reference voltage is correctly set. Check the sensing connections to rule out an open circuit. If the problem persists, the AVR may be faulty and require replacement.
  • R
    Ryan RichardsSep 1, 2025
    How to fix unstable voltage on a Sincro SK160 SA1 Inverter?
    • M
      maryhaydenSep 1, 2025
      If your Sincro Inverter's voltage is unstable, there are a few things you can check. First, make sure the AVR stability is correctly set by checking the correct Dip switches position and adjusting stability with the ST trimmer. Also, check for oscillations in engine speed using a frequency meter. If these steps don't resolve the issue, the AVR may be faulty and need to be replaced.

Summary

Safety Recommendations

Intended Use

Introduction

Control of ID plate

Checks the generator's identification plate against order specifications.

Voltage Regulation System Principles

Mechanical and Electrical Specifications

Installation

Lifting

Instructions for safely lifting the generator using suitable equipment.

Mounting on engine

Procedure for mounting the generator onto the engine, including torque specs.

Connections and Earthing

Guidelines for electrical connections and proper grounding of the generator.

Preliminary Controls

Checks to perform before starting the generating set.

Aftersales Assistance and Maintenance

Control and Check Procedures

Procedures for checking the condition of windings, diodes, and bearings.

Component Removal and Replacement

Detailed steps for removing and replacing various generator parts.

Troubleshooting

Common faults, their possible reasons, and suggested remedies.

Cleaning

Dismantling and Disposal

Spare Parts and Aftersales

Aftersales Procedure and Contact Addresses

Guidelines for contacting service and obtaining assistance.

Shipment

Instructions for shipping products for repair.

Warranty