S
ERIE
SK160
Manuale di uso e manutenzione
Use and Maintenance manual
Manuel d’utilisation et de maintenance
Bedienungs- und Wartungsanleitungen
Manual de uso y mantenimiento
103660
REV02
09/2018

Table of Contents

Questions and Answers

  • D
    Daniel BanksAug 9, 2025
    What to do if my Sincro SK160 CB1 Inverter has no voltage?
    • M
      Mr. Richard WebsterAug 9, 2025
      If your Sincro Inverter shows no voltage, several issues could be the cause. First, check all connections to ensure they are secure. A faulty AVR could be the problem; check the fuse and consider replacing the AVR. Also, inspect the rectifier bridge. An open stator exciter circuit or a main winding fault could also be responsible; check the stator/rotor windings resistances and insulation. In some cases, the machine may be demagnetized; excite the alternator by applying a 6-12 voltage across the exciter terminals for a second, respecting the polarities while the engine is running.
  • W
    wrightdianeAug 16, 2025
    Why is my Sincro SK160 CB1 Inverter voltage so low?
    • C
      christian18Aug 16, 2025
      If your Sincro Inverter is showing low voltage, try these steps: * Adjust the voltage using the potentiometer «V» on the AVR to set the reference voltage to the desired value. * Check and adjust the under-frequency protection value for the nominal frequency (50Hz or 60Hz). * Verify the engine speed to ensure it is correct, as a low engine speed can cause low voltage. * If these steps don't work, the AVR may be faulty and need replacement.
  • D
    David RiceAug 25, 2025
    What causes high voltage in a Sincro SK160 CB1?
    • R
      robertsjoannaAug 25, 2025
      If your Sincro Inverter is producing high voltage, the issue may stem from several causes. Begin by adjusting the voltage with the potentiometer «V» on the AVR to ensure the reference voltage is correctly set. Check the sensing connections to rule out an open circuit. If the problem persists, the AVR may be faulty and require replacement.
  • S
    Samuel WalshAug 31, 2025
    How to fix unstable voltage on a Sincro SK160 CB1?
    • S
      sbarberAug 31, 2025
      If your Sincro Inverter's voltage is unstable, there are a few things you can check. First, make sure the AVR stability is correctly set by checking the correct Dip switches position and adjusting stability with the ST trimmer. Also, check for oscillations in engine speed using a frequency meter. If these steps don't resolve the issue, the AVR may be faulty and need to be replaced.

Summary

Safety Recommendations

General Safety Guidelines

Covers essential safety precautions for installation, use, maintenance, and handling of the generator.

Safety Symbols Explanation

Defines the meaning of warning symbols like IMPORTANT, CAUTION, WARNING, and DANGER.

Intended Use

Voltage Regulation System

AVR System Function

Explains the operating principles of BL4-U and RD2 AVR systems and frequency control.

Installation

Lifting Procedures

Guidelines for safely lifting the generator using appropriate equipment and load capacity.

Mounting on Engine

Instructions for mounting the generator onto the engine, including screw types and seat cleaning.

Connections and Earthing

Guidance on electrical connections, cable sizing, and proper earthing of the generator housing.

BL4-U AVR Settings

Details on setting BL4-U AVR parameters like voltage, stability, and underspeed protection.

RD2 AVR Settings

Instructions for adjusting RD2 AVR parameters including voltage, stability, and underspeed protection.

Aftersales Assistance and Maintenance

Component Removal and Replacement

Details on removing and replacing key generator components like bearings, rotor, and exciter.

Troubleshooting Guide

Identifies common faults with possible causes and remedies for voltage and stability issues.

Dismantling and Disposal

Spare Parts and Aftersales

Warranty Information

Sincro SK160 CB1 Specifications

General IconGeneral
Rated Output Power160W
Output Power160W
Input Voltage12V DC
Output Voltage230V AC
Frequency50Hz
ProtectionOverload, Short Circuit, Over Temperature