User Manual of A90 Series Inverter
94
Lower limit of PID
output
0.00-100.00 (0.00: invalid)
PID integral
separation threshold
0.00-100.00 (100.00% = invalid
integral separation)
PID feedback
filtering time
PID output filtering
time
Upper limit detection
value of PID
feedback
disconnection
0.00-100.00; 100.00 = invalid
feedback disconnection
Lower limit detection
value of PID
feedback
disconnection
0.00-100.00; 0.00 = invalid
feedback disconnection
Detection time of PID
feedback
disconnection
PID sleep control
options
0: Invalid
1: sleep at zero speed
2: sleep at lower frequency limit
3: sleep with tube sealed
0.00-100.00 (100.00 corresponds
to the PID setting feedback range)
Multi-segment PID
setting 1
0.0 to PID setting feedback range
F09.03
Multi-segment PID
setting 2
0.0 to PID setting feedback range
F09.03
Multi-segment PID
setting 3
0.0 to PID setting feedback range
F09.03
Coefficient of
wake-up action point
0.0-100.0 (100% corresponds to
PID setting)
Pipeline network
alarm overpressure
0.0 to pressure sensor range
F09.03