Check:
Adjusting:
1. Set the machine to maximum stitch length.
2. Turn handwheel toward the front of the machine until feed dog (A) is in its most
forward position.
3. There should be a clearance of 0,38 mm - 0,50 mm between the center bar of feed
dog (A) and the edge of the center slot of the needle plate.
1. Remove the free-arm extension table, arm top cover, face plate and front and rear
covers.
2. Loose nut (C).
3. Turn eccentric screw (B) clockwise or counterclockwise as required to obtain correct
feed dog throw.
4. Tighten nut (C).