38
Service Manual
Feed Lifting Lever Assembly
(For models equiped with drop feed)
Removal:
1. Set feed regulator dial at number “5” (maximum stitch lenght).
2. Turn handwheel toward the front of the machine to bring the feed dog to its furthest
rear position.
3. Remove the free-arm extension plate, bed bottom cover and extension table bottom
cover.
4. Remove screws (G) to clear the eccentric pin (F) from clamp (D).
5. Remove retaining ring (J), the drop feed selector lever (K) and washer (L).
6. Remove feed lifting lever assembly (C).
Replacement:
1. Replace these parts the same way as described above, but in a reverse order.
2. Position the eccentric stud (F) making sure spacer (A) is positioned with the hole
offset against the feed lifting lever bushing.
3. Adjust feed dog height related to needle plate surface (see pages 103-104).
4. Be sure spring (B) is properly located in the hole of the casting and inserted over the
nib in the feed lifting lever (C).
P/N 358426002