4.5 - Cleaning the machine
ATTENTION!
Disconnect the machine from the mains electricity before cleaning.
Do not clean the machine using a jet of water.
Use non-toxic detergents only, expressly intended for clearing components coming
into contact with foodstuffs. DO NOT use chlorine-based detergents.
DO NOT use ethyl alcohol to clean the Plexiglas dome.
The Plexiglas lid be cleaned regularly with a soft, damp cloth, using cold or warm
water, with a small amount of neutral detergent.
It is recommended to avoid:
- the use of products containing: denatured ethyl alcohol, solvents in general,
Benzene, Trichloroethylene
- the use of abrasive materials and contact with sharp objects
Drying
When the lid has been cleaned, it can be dried using a slightly damp chamois
cloth, without rubbing hard.
4.6 - Vacuum pump heating
During the winter period, in the morning it is recommended to briefly
pre-heat the pump in order to fluidify the oil before it goes into
circulation:
- Position the master switch (ref. 1 fig. 4.6.1) at ON.
- Turn the suction cock to close (ref. 5 fig. 4.6.1)
- Press the UP key 3 times (ref. 3 fig 4.6.1)
The machine will perform an oil heating cycle.
The duration of the cycle is 15 minutes.
If the operator wants to interrupt the cycle before it ends,
he must press the switch-on key ref. 2 fig 4.1.1.
N.B. This operation must only be performed with the
intake cock closed.
5 Controls and maintenance
5.1 - Controls and maintenance
Access to the internal part of the machine is reserved exclusively to our
specialised technician.
If the machine is accessed voluntarily, the manufacturer declines all civil and penal
liability regarding any accidents or damage caused to persons or objects.
All electric components are protected within the machine body and the relative
guard must be removed in order to gain access. Whenever access must be made,
remove the plug from the electric control board current socket.