EasyManua.ls Logo

Sirocco Eco4 E4 HE Plus - Page 9

Sirocco Eco4 E4 HE Plus
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
The current versions of BS1289 and BS EN 1806 recommend that there should be an air
space or insulation between the flue blocks and the plaster because heat transfer may cause
cracking on directly plastered flues.
However, generally this appliance is suitable for installations under all circumstances unless
there is a history of cracking problems, remember that faults such as cracking may be caused
by poorly built and restrictive flues and therefore is not the responsibility of the manufacture
of this appliance.
Any existing draught device situated under the fireplace must be sealed off.
The opening area must be non-combustible
.
The appliance requires a hearth with non-combustible surface of at least 300mm in depth and 12mm thick.
The top surface must be at least 50mm above the surrounding flooring level, or be surrounded by a raised
edge or fender 50mm high.
To enable the product of combustion to be cleared properly up the flue, the outlet at the back of the
appliance must have a 50mm minimum clearance between it and the back wall of the opening or any other
obstruction.
The area immediately above the outlet must form a smooth path into the flue.
The fireplace or builders open must be reduced to suite the appliance both side to side and the full depth
of the appliance, a decorative back panel i.e. marble, granite etc. must not be used as a closure plate for
the appliance please see below.
TOP VIEW
Any type of fire surround used with this appliance must be adequately sealed to the wall and floor; a
combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions
given below.
From Hearth to Underneath of Shelf with a depth of 150mm is 800mm add 12.5mm in height for every
25mm increase to the projection of the shelf depth.
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl
and embossed paper) positioned too close to the appliance may discolour or scorch.

Related product manuals