Language | English |
Crucial safety guidelines for handling the device and potential hazards.
Important information and procedures for performing software updates on the unit.
Explains help codes (Hxxx) caused by operator errors and required actions to resolve them.
Details error codes (Ex yy zz) displayed on the Easypad/Multipad, providing error type, location, and troubleshooting info.
Comprehensive list of error codes, their descriptions, required actions, and corresponding page references.
Detailed procedures and diagrams for checking CAN bus connections and identifying faults.
Steps for visual inspection, voltage measurement, and replacement of circuit boards.
Troubleshooting steps for high device leakage current, involving checking cable shields and replacing components.
Troubleshooting guide for X-RAY control signal path issues specific to units with board DX41.
Troubleshooting guide for X-RAY control signal path issues on units with HW version BA or higher.
Crucial warnings and notes before performing system adjustment procedures.
Explains how to access and navigate the Diaphragm/System Adjustment menu in SIDEXIS XG.
Detailed procedures for adjusting the panoramic X-ray unit, including needle phantom usage.
Procedures for adjusting the cephalometer, including functional tests and specific settings.
Guide for adjusting the TSA sensor, focusing on image evaluation and parameter settings.
Procedures for running service routines that require the SIDEXIS software.
Comprehensive guide to various configuration settings, including hardware version, language, remote control, and PPE display.
Procedures for height adjustment, including setting travel limits and testing sensors.
Procedures for displaying and calibrating center positions of Ceph scan sensor axes and secondary diaphragm axes.
Essential safety checks, including ground wire and leakage current tests, before and after repair.
Detailed steps for preparing, moving the slide, and replacing the height adjustment motor/spindle.
Procedures for replacing the ring motor, including reusing coupling and installing the new motor.
Critical procedure for replacing the X-ray tube assembly, emphasizing safety precautions and software updates.
Important notes and procedures for replacing circuit boards like DX1, DX11, DX32, DX41, DX42, DX89, DX91.
Procedures for checking height adjustment, including motor, rod, limit switches, and audible signals.
Procedures for checking kV actual value, radiation time, and tube current with specific service routines and test equipment.
Detailed steps for measuring protective ground wire resistance and checking connections.
Procedure for measuring unit leakage current using an automatic tester or manual methods.