EasyManua.ls Logo

Sizewise 33060400 - User Manual

Sizewise 33060400
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Evolution®
User Manual
Doc. #8034, Rev. 12.0, Rev. Date: 3/01/2021
MFG-0020I-1219

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sizewise 33060400 and is the answer not in the manual?

Summary

Hazard and Connection Symbols

Pinch Point Hazard Identification

Warns about pinch points and required clearance.

Important Safety Instructions

Specifications and Setup Warnings

Information on capacity, damage, and set-up procedure risks.

Operational Safety and Usage

General Operating Precautions

Covers caster locking, cord safety, and moving parts.

Electrical Safety and Handling

Precautions for cord positioning, electrical hazards, and pinch points.

Bed Use and Safety Guidelines

Patient Entry, Exit, and Reaching Safety

Steps for safe patient movement and reaching.

Side Rail and Transfer Safety

Discusses side rail securing, entrapment, and transfer procedures.

Electrical Safety and Maintenance Tips

Advises on ground connection and power cord repair.

Electromagnetic Compatibility and Interference

EMC Guidelines and Interference Warnings

Advises on avoiding interference from radio waves and devices.

Maintenance and Troubleshooting

Troubleshooting Common Bed Issues

Provides solutions for bed operation and component problems.

Device Information Overview

SW Evolution Bed Description

Electric bed for patient safety, adjustable height, and load capacity.

SW Rest Secure System (RSS) Description

System to alert care providers of patient exit or fall risk.

SW Evolution Specifications

Quality Standards and Technical Details

Details quality standards, electrical rating, duty cycle, and dimensions.

SW Rest Secure System Specifications

Control Module Technical Details

Details housing, connectors, power, and weighing function specs.

Hand Control Specifications

Hand Control Features and Functions

Describes housing, connectors, operating current, display, and functions.

Unpacking and Setup Procedures

Parts Breakdown and Inspection

Instructions for inspecting for damage and verifying components.

Bed Assembly Steps

Assembling Bed Frame Sections

Steps for connecting head and foot sections using bolts.

Connecting Bed Components

Power and Control Cable Connections

Steps for connecting power, foot, hand, and actuator cables.

Final Bed Setup and Testing

Powering Up and Function Verification

Plugging into outlet, checking hand control functions.

Side Rail Installation

SW Rest Secure System Setup

Bed Exit Alarm Configuration

Scale System: Zeroing the Scale

Scale System Operations

Protocol Timer and Alert Settings

SW Rest Secure System Default Settings

Resetting to Factory Variables

Procedure to restore default settings, including alarms and language.

Operating Instructions Overview

Hand Control Basic Operation

Basic instructions for using the hand control and safety warnings.

Bed Operation Controls

Hand Control Button Functions

Details operations for head, bed, foot, and Trendelenburg controls.

Bed Usage Precautions

Electrical Safety and Pinch Hazards

Warns about cord condition, power supply, and pinch injuries.

Rest Secure System Hand Control

Hand Control Interface Explained

Explains features like LCD display, microphone, LED indicators, and buttons.

Bed Exit Alarm Functionality

Using the Bed Exit Alarm System

Alerts care providers to patient exit or fall risk.

Setting Bed Exit Alarm Sensitivity

Guides on selecting high, medium, or low sensitivity settings.

Scale System Usage and History

Using the Scale and Accessing Weight History

How to weigh patients and view stored weight data.

Protocol Timer Functions

Utilizing the Protocol Timer

Alerts care providers for patient checks at set intervals.

Bed Exit Alarm Customization

Scale System Adjustments

Scale System Unit Lock Feature

Proper Bed Usage and Safety

Patient Entry, Exit, and Reaching Safety

Steps for safe patient movement and reaching.

Side Rail Operation and Safety

Emergency Battery Backup System

Bed Rail Entrapment Zones

Bed Rail Entrapment Standards

Safety Tips and Compliance

Electromagnetic Interference (EMI) Details

Electromagnetic Interference (EMI) Warnings

Radio Wave Source Warnings

Warns about effects of radio waves and personal devices on bed operation.

Electromagnetic Interference Management

General Safety Precautions

Pinch Point Hazard Identification

Transport and Storage Safety

Maintenance Schedule and Checklist

Troubleshooting SW Evolution Bed

Resolving Unresponsive Functions and Power Issues

Solutions for unresponsive functions and battery power issues.

Troubleshooting SW Rest Secure System

Resolving Common Error Messages and Issues

Addresses load cell errors, power issues, and weight readings.

Sizewise 33060400 Specifications

General IconGeneral
BrandSizewise
Model33060400
CategoryMedical Equipment
LanguageEnglish

Related product manuals