EasyManua.ls Logo

SKY-WATCHER SynScan - Part VIII: Auxiliary Functions; Editing Date, Time, Coordinates, Time Zones, and Daylight Saving Time; Re-Aligning the Mount; Show Position

SKY-WATCHER SynScan
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
PART VIII : AUXILIARY FUNCTIONS
8.10 Changing Polar Scope Illumination Level
8.11 Identifying Objects
• H.C. Firmware: The rmware version of the SynScan hand controller.
• Database: The database version of the SynScan hand controller
• H.C. Hardware: The hardware version of the SynScan hand controller.
• Motor Controller: The rmware version of the motor controller of the mount.
• H.C. Serial #: The serial number of the SynScan hand controller.
This function applies only to certain Sky-Watcher’s equatorial mounts that are equipped with
a polar scope illuminator.
1. Access the menu “Utility Func \ Polar Scope LED” and press the ENTER key.
2. Use the Left/Right direction keys to adjust the illumination level. Press the ENTER key to
conrm and exit.
After aligning the mount, the SynScan hand controller can be used to identify the object to
which the telescope is pointing.
1. Center the object to be identied in the telescope’s eyepiece.
8.6 Display Temperature
8.8 Display Polaris Position
8.7 Display Power Voltage
8.9 Display Polar Alignment Error
Access the menu “Utility Func \ Show Information \ Temperature” and press the ENTER key to
display the current temperature. Press the ESC key to exit.
Access the menu “Utility Func \ Show Information \ Polaris Pos.” and press the ENTER key. The
screen will display “Polaris Position in P.Scope = HH:MM”. Press the ESC key to exit.
When using a polar-scope to do the polar alignment, users can imagine the large circle in
the FOV of a polar-scope as a clock’s face with 12:00 at the top, and put the Polaris at the
HH:MM” position of the large circle.
Access the menu “Utility Func \ Show Information \ Power Voltage” and press the ENTER key to
display the power voltage applied to the mount. Press the ESC key to exit.
Access the menu “Utility Func \ Show Information \ P.A Error” and press the ENTER key. The
screen will display “Mel=+DDD
o
MM’SS Maz=+DDD
o
MM’SS”. The “Mel” value is the polar align-
ment offset in elevation, and the “Maz” value is the polar alignment offset in azimuth. These
data is valid only after a 2-star alignment or a 3-star alignment.