Section 6 – Additional Procedures Refuel
6.5-2 Replace the propane cylinder
(optional equipment)
WARNING
Obey all national, state/provincial/territorial, and
local health and safety rules for propane handling.
If you do not obey, there is a risk of death or
serious injury.
WARNING
When you replace a liquid propane gas cylinder,
do an inspection of all the connections for damage
or missing parts. If you do not obey, there is a risk
of death or serious injury.
WARNING
Explosion hazard. Do not start the MEWP if you
smell liquid propane gas. Liquid propane gas is
heavier than air. It collects in low areas. A flame
or spark can cause a fire or explosion. Lock and
tag the MEWP for servicing or repair. If you do not
obey, there is a risk of death or serious injury.
Remove the propane cylinder
1. Stop the engine.
2. Push the emergency-stop button on the base
control console.
3. Turn the propane cylinder valve clockwise to
stop the fuel supply to the engine.
4. Pull the emergency-stop button. Start the
engine and let it stop by itself.
5. Move the fuel switch to the liquid propane gas
position.
6. Start the engine again to make sure the fuel lines
are empty.
7. Push the emergency-stop button.
8. Turn the propane tank hose fitting
counterclockwise to detach the coupling.
Disconnect the hose from the empty propane
cylinder.
9. Pull on the metal clips to loosen the two propane
cylinder straps. Disconnect the straps from the
hooks.
10. Remove the empty propane cylinder.
Install the propane cylinder:
1. Push the emergency-stop button on the base
control console.
2. Put the new propane cylinder on the mounting
bracket. Make sure the metal peg goes through
the hole on the propane cylinder rim.
3. Reconnect the propane cylinder straps to the
hooks and fasten them tightly.
4. Attach the hose to the new propane cylinder.
Turn the fitting clockwise to tighten it.
5. Apply mild soapy water to the propane hose
connection.
6. Open the valve one quarter-turn
counterclockwise. Do an inspection for gas
leaks.
7. If there are no gas leaks, fully open the propane
cylinder valve.
8. Wipe off the soapy water after the inspection is
complete.
To order go to Discount-Equipment.com

Table of Contents

Other manuals for Skyjack SJ46 AJ+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ46 AJ+ and is the answer not in the manual?

Skyjack SJ46 AJ+ Specifications

General IconGeneral
BrandSkyjack
ModelSJ46 AJ+
CategoryBoom Lifts
LanguageEnglish

Related product manuals