SJ 86T
December 2007 Page 39
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the MEWP.
FAMILIARIZATION
• Test Driving Function
1. Ensure path of intended motion is clear.
2. Ensure boom is in stowed position and y
boom fully retracted.
3. Depress and hold footswitch.
4. Slowly move drive/steer controller in
“ ” forward or “ ” reverse direction
until MEWP begins to move, and then
return handle to center position.
Result: MEWP should move in forward
or reverse direction, and then come to a
stop.
• Test Driving Speed
1. Depress and hold footswitch.
2. Raise “ ” main boom approximately
4 m (14 ft.) and then slowly move drive/
steer controller to full drive position.
Result: The maximum achievable drive
speed should be signicantly less than
stowed drive speed.
3. Lower boom to stowed position.
4. Extend “ ” y boom approximately
30 cm (12 inch.) and then slowly move
drive/steer controller to full drive position.
Result: The maximum achievable drive
speed should be signicantly less than
stowed drive speed.
Horn
Emergency Power
Switch
Emergency Stop
Engine Start/On/
Off Switch
Platform Leveling
Override Switch
Drive/Steer
Controller
Section 2 - Familiarization Function Tests