Operating Manual SB3-5TL-21-BE-en-10 55
SMA Solar Technology AG 13 Technical Data
13.1.2 Sunny Boy 4000TL / 5000TL
DC Input
AC Output
SB 4000TL-21 SB 5000TL-21
Maximum DC power at cos φ = 1 4,200 W 5,200 W
Maximum input voltage 450 V 550 V
MPP voltage range 175 V to 500 V 175 V to 500 V
Rated input voltage 400 V 400 V
Minimum input voltage 125 V 125 V
Initial input voltage 150 V 150 V
Maximum input current 30 A 30 A
Maximum input current per string
*
* Maximum permitted current allowed through one DC connector.
15 A 15 A
Number of independent MPP inputs 2 2
Strings per MPP input 2 2
SB 4000TL-21 SB 5000TL-21
Rated power at 230 V, 50 Hz 4,000 W 4,600 W
Maximum apparent AC power 4,000 VA 5,000 VA
Rated grid voltage 230 V 230 V
Nominal AC voltage 220 V / 230 V /
240 V
220 V / 230 V /
240 V
AC voltage range
*
180 V to 280 V 180 V to 280 V
Nominal AC current at 220 V 18.2 A 20.9 A
Nominal AC current at 230 V 17.4 A 20.0 A
Nominal AC current at 240 V 16.7 A 19.2 A
Maximum output current 22 A 22 A
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
< 2%, and AC power > 50% of the rated power
≤4% ≤4%
Rated power frequency 50 Hz 50 Hz