EasyManua.ls Logo

SMA SUNNY MINI CENTRAL 6000TL - Sunny Mini Central 7000 TL

SMA SUNNY MINI CENTRAL 6000TL
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data SMA Solar Technology AG
78 SMC6-8TL-IEN101040 Installation Guide
11.2 Sunny Mini Central 7000TL
DC Input
* The maximum open circuit voltage, which can occur at a cell temperature of -10 °C, may not exceed the maximum input voltage.
AC Output
Maximum DC power at cos ϕ = 1 P
DC
7,200 W
Maximum DC voltage * U
DC
max
700 V
MPP voltage range U
PV
333 V 500 V
DC nominal voltage U
DC nom
350 V
Minimum DC voltage U
DC min
330 V
Start voltage, adjustable U
PV Start
400 V
Maximum input current I
PV max
22 A
Number of MPP trackers 1
Maximum number of parallel strings 4
Voltage ripple of input voltage U
pp
<10%
Internal consumption during operation < 10 W
AC nominal power at 230 V AC, 50 Hz P
AC nom
7,000 W
Maximum AC apparent power S
AC max
7,000 VA
Nominal AC current I
AC nom
31 A
Maximum output current I
AC max
31 A
Maximum fuse protection 50 A
Harmonic distortion of output current at
AC T
HD
voltage < 2 %,
AC power > 0.5 AC nominal power
K
IAC
< 3 %
Nominal AC voltage U
AC nom
220 V / 230 V / 240 V
AC voltage range U
AC
180 V 260 V
AC grid frequency f
AC nom
50 Hz / 60 Hz
Operating range at AC grid frequency f
AC
50 Hz: 45.5 Hz … 54.5 Hz
60 Hz: 55.5 Hz … 64.5 Hz
Power factor at nominal AC power cos ϕ 1
Supply phases 1
Connection phases 1
Overvoltage category as per
AUS/NZS 60950.1:2003
II
Overvoltage category as per EN 50178:1998 III
Test voltage (DC) 2.15 kV
Test surge voltage 4 kV

Table of Contents

Other manuals for SMA SUNNY MINI CENTRAL 6000TL

Related product manuals