Technical Data SMA Solar Technology AG
82 SMC6-8TL-IEN101040 Installation Guide
Mechanical data
Climatic Conditions
* according to DIN EN 50178:1998-04, installation type C, class 4K4H
** according to DIN EN 50178:1998-04, transport type E, class 2K3
Features
General data
Protective equipment
Surge testing voltage with serial interface 6 kV
Internal consumption in night mode 0.25 W
Width x height x depth 468 mm x 613 mm x 242 mm
Weight 33 kg
Extended temperature range * − 25 °C … +60 °C
Extended humidity range * 0 % … 100 %
Extended air pressure range * 79.5 kPa … 106 kPa
Temperature range ** − 25 °C … +70 °C
Operation temperature range − 25 °C … +60 °C
Maximum operating altitude above mean sea
level
3,000 m
Topology Transformerless
Cooling concept OptiCool
Fan connection Designed for safe disconnection
In accordance with DIN EN 50178:1998-04
Protection rating in accordance with
DIN EN 60529
IP65
Protection class I
Noise emission (typical) ≤ 40 dB(A)
All-pole DC switch-disconnector Electronic Solar Switch,
DC plug system SUNCLIX
DC overvoltage protection Thermally monitored varistors
Personal protection (R
iso
> 1 M Ω ) Insulation monitoring
Pole confusion protection Short circuit diode
AC short circuit protection Current control
All-pole AC disconnection unit Automatic disconnection device
SMA Grid Guard 2.1