04
22
COMMISSIONING
Incorrect connection of the system to the
power supply can damage the system.
Get the electrical connections established
only by an electrician with the appropriate
qualification.
Commissioning,
electrical connection
Minimum cross-section for cabling
2.5 mm2 to 30 m length is required as the
minimum cross-section. The cross-sec-
tions prescribed as per the applicable stan-
dard for electricians must be adhered to.
Installing the cables
Cables must always be installed in an ins-
tallation pipe that is approved for outside
working. If possible, a tape with a warning
via the electrical cable must also be ins-
talled. The exact requirements for this
must be verified and adhered to, depen-
ding on the countries.
ELECTRICAL CONNECTIONS
Cable length cable cross-section for power
supply and supply cable
15 m to 30 m 3 x 2,5 mm
2
AWG 14
From 30 m onwards
the local standards
must be followed
Note: Home connection must be secured with the
C16 line protection
RISK OF DEATH
Connecting the system incorrectly to the
power supply can cause current surges that
can result in death. Get the electrical con-
nections established only by an electrician
with the appropriate qualification.
Incorrect and incomplete earthing can cause
current surges. Get the earthing done only by
an electrician with the appropriate qualifica-
tion. Test earthing with the suitable measu-
ring equipment.
!