ACC4100 Diesel Air Compressor Controller User Manual Page 47 of 52
14.9 DEUTZ EMR2
Engine type: Volvo-EDC4.
Table 29 F Connector
Terminals of controller
F connector
Remark
Fuel relay output
Expansion 30A relay,
providing battery voltage
for 14; Fuse is 16A.
Starting relay output
-
Connect to starter coil directly.
-
1
Connect to battery negative pole.
CAN(H)
12
Impedance 120Ω connecting line is
recommended.
CAN(L)
13
Impedance 120Ω connecting line is
recommended.
14.10 JOHN DEERE
Engine type: John Deere.
Table 30 21-pin Connector
Terminals of controller
21 pins connector
Remark
Fuel relay output
G, J
Starting relay output
D
CAN(H)
V
Using impedance 120Ω connecting line.
CAN(L)
U
Using impedance 120Ω connecting line.
14.11 MTU MDEC
Suitable for MTU engines, 2000 series, 4000series; Engine type: mtu-MDEC-303.
Table 31 X1 Pin Connector
Terminals of controller
X1 connector
Remark
Fuel relay output
BE1
Starting relay output
BE9
-
E
Communication shielding line (connect with
ECU this terminal only).
CAN(H)
G
Using impedance 120Ω connecting line.
CAN(L)
F
Using impedance 120Ω connecting line.