PRODUCT NAME
Electric Actuator /Slider Type
《Step motor/Servo motor》
MODEL / Series
LEF Series
Applicable models: LEFS, LEFB
Doc. no. LEF-OM00213
This manual describes the actuators operation in combination with the LEC*6 series controllers.
Refer to the manual relevant to the controller being used for full operating instructions.
<Controller>
LEC Series
2021-05-2010:32
DW913599

Other manuals for SMC Networks LEFS Series

Questions and Answers

  • J
    James DuarteAug 22, 2025
    Why does my SMC Networks Controller show 'Phase Det ALM /code: 1-193' at the initial stage?
    • M
      Madeline GreenAug 22, 2025
      If the SMC Networks Controller generates an alarm for 'Phase Det ALM /code: 1-193' when power is supplied, it could be due to several reasons. First, the cable might not be properly installed or has been disconnected; check the cable installation. Second, the load or resistance being applied to the actuator might constantly exceed the actuator's specification; keep the load and resistance within the specified range and check the actuator mounting condition. Third, the controller and actuator combination might not be correct; the controller and actuator combination at the time of shipment should not be changed. Fourth, excessive external force is being applied, including vibration or impact load; operate within the specified range.
  • M
    Monica ClarkAug 31, 2025
    How to fix SMC Networks Controller 'Stroke limit/code: 1-052' alarm?
    • B
      Brandon WilsonAug 31, 2025
      If the SMC Networks Controller generates an alarm for 'Stroke limit/code: 1-052' and operation is not completed, it means the moving distance exceeds the 'Stroke(+) / 'Stroke(-). Check the value of the 'Position' of step data and the value of the 'Stroke(+) / 'Stroke(-)' of the basic parameter.
  • B
    Brian Martinez IIINov 10, 2025
    What to do if SMC Networks Controller operation is not completed due to 'Over load' or 'Posn failed' alarm?
    • B
      bmorrisNov 11, 2025
      If the SMC Networks Controller displays the 'Over load/code: 1-148' or 'Posn failed/code: 1-149' alarm and operation is not completed, it could be due to several reasons. First, excessive external force, vibration, or impact load might be the cause; ensure operation is within the specified range. Second, the power supply may lack sufficient capacity; verify the power consumption and replace the power supply if needed. Third, the load or resistance applied to the actuator might exceed the specified range; use within the specified range and check the actuator's mounting. Fourth, pushing operation might be performed at 'Positioning operation'; review the step data. Fifth, the cable might not be connected correctly; confirm the cable connection. Sixth, the actuator might have pinched the workp...