PRODUCT NAME
Electric Actuator Slider Type
Step motorServo motor
MODEL / Series
LEF Series
Applicable models: LEFS, LEFB
Doc. no. LEF-OM00213
This manual describes the actuators operation in combination with the LEC*6 series controllers.
Refer to the manual relevant to the controller being used for full operating instructions.
<Controller>
LEC Series
2021-05-2010:32
DW913599

Other manuals for SMC Networks LEFS25

Questions and Answers

  • D
    Diane FloresAug 5, 2025
    Why does my SMC Networks Controller show 'Phase Det ALM /code: 1-193' at the initial stage?
    • J
      Jacob MartinezAug 5, 2025
      If the SMC Networks Controller generates an alarm for 'Phase Det ALM /code: 1-193' when power is supplied, it could be due to several reasons. First, the cable might not be properly installed or has been disconnected; check the cable installation. Second, the load or resistance being applied to the actuator might constantly exceed the actuator's specification; keep the load and resistance within the specified range and check the actuator mounting condition. Third, the controller and actuator combination might not be correct; the controller and actuator combination at the time of shipment should not be changed. Fourth, excessive external force is being applied, including vibration or impact load; operate within the specified range.
  • S
    Sharon SilvaAug 14, 2025
    How to fix SMC Networks Controller 'Stroke limit/code: 1-052' alarm?
    • K
      Kevin BartonAug 14, 2025
      If the SMC Networks Controller generates an alarm for 'Stroke limit/code: 1-052' and operation is not completed, it means the moving distance exceeds the 'Stroke(+) / 'Stroke(-). Check the value of the 'Position' of step data and the value of the 'Stroke(+) / 'Stroke(-)' of the basic parameter.
  • N
    nwellsOct 25, 2025
    What to do if SMC Networks Controller operation is not completed due to 'Over load' or 'Posn failed' alarm?
    • W
      Whitney WebsterOct 25, 2025
      If the SMC Networks Controller displays the 'Over load/code: 1-148' or 'Posn failed/code: 1-149' alarm and operation is not completed, it could be due to several reasons. First, excessive external force, vibration, or impact load might be the cause; ensure operation is within the specified range. Second, the power supply may lack sufficient capacity; verify the power consumption and replace the power supply if needed. Third, the load or resistance applied to the actuator might exceed the specified range; use within the specified range and check the actuator's mounting. Fourth, pushing operation might be performed at 'Positioning operation'; review the step data. Fifth, the cable might not be connected correctly; confirm the cable connection. Sixth, the actuator might have pinched the workp...

Summary

Safety and Compliance Information

Hazard Definitions and General Safety

Defines hazard levels (Caution, Warning, Danger) and general safety rules.

Special Conditions and Product Warranty

Guidelines for specific environments, warranty, and compliance requirements.

Operation Setup and Control Methods

Initial Setup and Preparation

Lists required items and preparation steps for initial operation.

Controller Software and Teaching Box Usage

Instructions for using the controller software and teaching box.

Step Data Configuration

Procedures for changing step data for positioning operations.

Specifications and Product Structure

Ball Screw Drive Specifications

Technical specifications for LEF series ball screw drive models.

Belt Drive Specifications

Technical specifications for LEF series belt drive models.

How to Order and Construction Details

Guides for ordering actuators and diagrams of their construction.

System Outline and Operation Procedures

System Construction and Setting Functions

Overview of system setup and available setting functions.

Step Data and Parameter Settings

Detailed methods for setting step data and basic parameters.

Operation Procedures and Signals

Input/output signals required for various operational procedures.

Origin Setting and Offset Adjustment

Procedures for setting and modifying origin and offset parameters.

Wiring, Mounting, and Precautions

Wiring and General Precautions

Safety guidelines for wiring, connectors, and preventing electrical shock.

Design, Selection, and Mounting

Precautions for actuator design, selection, and proper mounting.

Slider Type Specific Precautions

Common precautions relevant to slider type actuators.

Maintenance and Troubleshooting

Maintenance, Belt, and Seal Band Procedures

Steps for maintenance, replacing belts, and handling dust seal bands.

Troubleshooting Common Actuator Issues

Common problems, their causes, and recommended countermeasures.