Electric Actuator/Slider Type
Ball Screw Drive
Series 25A-LEFS
LEFS16, 25, 32, 40
Step Motor
(Servo/24 VDC)
Servo Motor
(24 VDC)
Applicable stroke table
Standard
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950
1000
Manufacturable
stroke range [mm]
LEFS16
50 to 500
LEFS25
50 to 600
LEFS32
50 to 800
LEFS40
150 to 1000
* Strokes are manufacturable in 1 mm increments. Refer to the manufacturable stroke range. However, strokes other than those shown above are produced
as special orders. Consult with SMC for lead times and prices.
How to Order
r Motor type
Symbol
Type
Applicable size
Compatible
controllers/
driver
LEFS16 LEFS25 LEFS32 LEFS40
Nil
Step motor
(Servo/24 VDC)
LECP6
LECP1
LECPA
LECPMJ
A
Servo motor
(24 VDC)
LECA6
t Lead [mm]
Symbol
LEFS16 LEFS25 LEFS32 LEFS40
A
10 12 16 20
B
5 6 8 10
e
Motor mounting position
Nil
In-line
R
Right side parallel
L
Left side parallel
w Size
16
25
32
40
y Stroke [mm]
50
50
to
to
1000
1000
* Refer to the applicable stroke table.
Model
Stroke
[mm]
Caution
[CE-compliant products]
qEMC compliance was tested by combining the electric actuator LEF series and the controller
LEC series.
The EMC depends on the configuration of the customer’s control panel and the relationship with
other electrical equipment and wiring. Therefore conformity to the EMC directive cannot be
certified for SMC components incorporated into the customer’s equipment under actual
operating conditions. As a result it is necessary for the customer to verify conformity to the EMC
directive for the machinery and equipment as a whole.
wFor the servo motor (24 VDC) specification, EMC compliance was tested by installing a noise
filter set (LEC-NFA).
Refer to the WEB catalog for the noise filter set. Refer to the LECA Operation Manual for
installation.
[UL-compliant products]
When conformity to UL is required, the electric actuator and controller/driver should be used with a
UL1310 Class 2 power supply.
Series compatible with
secondary batteries
The actuator and controller/driver are sold as a package.
Confirm that the combination of the controller/driver and the actuator is correct.
<Check the following before use.>
q
Check the actuator label for model number (after "25A-"). This matches the controller/driver.
w Check Parallel I/O configuration matches (NPN or PNP).
* Refer to the operation manual for using the products. Please download it via our website, http://www.smcworld.com
RoHS
®
q w
q Accuracy
Nil
Basic type
H
High precision type
25A-LEFS
25
w
200
y
6N
!0
S
i
1
o
R
e
H
q r
B
t u
1
!1 !2
153
25A-P-B-P153-web修正-CS3e.indd 153 14.10.10 5:01:34 PM
A

Other manuals for SMC Networks 25A-LEFS Series

Questions and Answers

  • N
    nburnsAug 21, 2025
    Why does my SMC Networks Controller show 'Phase Det ALM /code: 1-193' at the initial stage?
    • O
      ocollinsAug 21, 2025
      If the SMC Networks Controller generates an alarm for 'Phase Det ALM /code: 1-193' when power is supplied, it could be due to several reasons. First, the cable might not be properly installed or has been disconnected; check the cable installation. Second, the load or resistance being applied to the actuator might constantly exceed the actuator's specification; keep the load and resistance within the specified range and check the actuator mounting condition. Third, the controller and actuator combination might not be correct; the controller and actuator combination at the time of shipment should not be changed. Fourth, excessive external force is being applied, including vibration or impact load; operate within the specified range.
  • R
    rebecca83Sep 1, 2025
    How to fix SMC Networks Controller 'Stroke limit/code: 1-052' alarm?
    • E
      ecarrollSep 1, 2025
      If the SMC Networks Controller generates an alarm for 'Stroke limit/code: 1-052' and operation is not completed, it means the moving distance exceeds the 'Stroke(+) / 'Stroke(-). Check the value of the 'Position' of step data and the value of the 'Stroke(+) / 'Stroke(-)' of the basic parameter.
  • M
    Michelle WilsonNov 10, 2025
    What to do if SMC Networks Controller operation is not completed due to 'Over load' or 'Posn failed' alarm?
    • C
      Corey FlemingNov 10, 2025
      If the SMC Networks Controller displays the 'Over load/code: 1-148' or 'Posn failed/code: 1-149' alarm and operation is not completed, it could be due to several reasons. First, excessive external force, vibration, or impact load might be the cause; ensure operation is within the specified range. Second, the power supply may lack sufficient capacity; verify the power consumption and replace the power supply if needed. Third, the load or resistance applied to the actuator might exceed the specified range; use within the specified range and check the actuator's mounting. Fourth, pushing operation might be performed at 'Positioning operation'; review the step data. Fifth, the cable might not be connected correctly; confirm the cable connection. Sixth, the actuator might have pinched the workp...

SMC Networks 25A-LEFS Series Specifications

General IconGeneral
BrandSMC Networks
Model25A-LEFS Series
CategoryController
LanguageEnglish