D-F9
D-Y7GL
Series LXF
∗
, LXP, LXS
Series LJ1
(non-standard motor)
Auto switch internal circuits
316
∗ Cannot be mounted on Series LXF with ball screw specification.
Switches
Solid State Switches
Applicable Actuators
Auto Switch Specifications
Auto switch part no.
Contact
Electrical entry
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F9N
NPN
28VDC or less
40mA or less
1.5V or less
(0.8V or less
at load current
of 10mA)
D-F9G
NPN
28VDC or less
40mA or less
1.5V or less
(0.8V or less
at load current
of 10mA)
D-F9B
In-line
2 wire
—
24VDC relay,
PLC
—
—
24VDC
(10 to 28VDC)
5 to 40mA
0.4V or less
80mA or less
D-F9P
N.O. (A contact)
PNP
—
80mA or less
0.8V or less
Red LED lights up when ON
D-F9H
PNP
—
80mA or less
0.8V or less
100
µ
A
or less at
24VDC 100
µ
A
or less at
24VDC
Red LED lights up when OFF
3 wire 3 wire
IC circuit, Relay, PLC
5, 12, 24VDC (4.5 to 28V)
10mA or less
IC circuit, Relay, PLC
5, 12, 24VDC (4.5 to 28V)
10mA or less
N.C. (B contact)
Auto switch part no.
Contact
Electrical entry
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-Y7GL
N.C. (B contact)
In-line
3 wire
NPN
IC circuit, Relay, PLC
5, 12, 24VDC (4.5 to 28V)
10mA or less
28VDC or less
40mA or less
1.5V or less (0.8V or less at load current of 10mA)
100µA or less at 24VDC
Red LED lights up when OFF
D-F9G, D-Y7GL
D-F9B
D-F9P, D-F9H
OUT
Black [White]
DC (+)
Brown [Red]
DC (–)
Blue [Black]
Main circuit
of switch
Main circuit
of switch
DC (+)
Brown [Red]
OUT
Black [White]
DC (–)
Blue [Black]
OUT (+)
Brown [Red]
OUT (–)
Blue [Black]
Main circuit
of switch
• Lead wire –––––––––––– Oil resistant heavy duty vinyl cord, ø2.7, 0.15mm² x 3 wire (Brown, Black, Blue [Red, White,
Black]), 0.18mm² x 2 wire (Brown, Blue [Red, Black])
• Insulation resistance ––– 50MΩ or more at 500VDC (between lead wire and case)
• Withstand voltage ––––– 1000VAC for 1 min. (between lead wire and case)
• Indication light –––––––– Lights when ON
• Ambient temperature ––– –10 to 60°C
•
Operating time ––––––––
1ms or less
• Impact resistance –––––-
1000m/s²
Lead wire colors inside [ ] are those prior to