Instructions for the installer
37
7.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary (1) 1.05 50 400 76 75
Semi-rapid (2) 1.75 65 500 127 125
Ultra-rapid (3) 3.90 91 + 46 1600 284 279
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary (1) 1.05 72 400
Semi-rapid (2) 1.75 97 500
Ultra-rapid (3) 3.90 130 + 75 1600
7.3 Arrangement of the burners on the hob
BURNERS