Instructions for the installer
Loosen screw C and push air regulator D to the
bottom.
With a 7 mm wrench, remove nozzle E and
replace it with the proper one (follow the
instructions on the reference tables for the type of
gas to be used). The torque wrench setting of the
nozzle must not exceed 3 Nm.
Regulate the air by sliding regulator D until
reaching distance “X” shown in the table in
paragraph “5.4 Regulation of primary air ”.
Lock regulator D by tightening screw C.
Rated
heating
capacity
(kW)
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown inpoint “5.6
Regulation of minimum for natural gas”.
CAUTION: for references A and B on
the lh UR and rh UR burners, see
drawings at side.
5.3 Regulation for natural gas
The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To
allow the unit to work with this type of gas, perform the same operations described in
paragraph “5.2 Regulation for LPG ”, but choose the nozzles and regulate the primary
air for natural gas, as shown in the following table and in paragraph “5.4 Regulation of
primary air ”.
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar