Conventional X-ray Inspection Units HI-SCAN
with HiTraX Electronics
User's guide for users with
supervisor access level
All rights reserved!
The reproduction, transmission or use of this document or its contents
is not permitted without express written authority. Offenders will be
liable for damages.
All rights, including rights created by patent grant or registration of a
utility model or design, are reserved. Modifications reserved.
95584681 01/01/09 © Smiths Heimann
SMITHS HEIMANN
www.smithsdetection.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Smiths detection HI-SCAN 6046si and is the answer not in the manual?

Smiths detection HI-SCAN 6046si Specifications

General IconGeneral
Energy140 kV
Conveyor Speed0.2 m/s
TypeX-ray scanner
Power Supply230 VAC ±10% / 50 Hz - 60 Hz
Image ProcessingReal-time image processing, Multi-energy imaging

Summary

Additional guide for users with supervisor access level

How to log in

Procedures and details for logging into the HI-SCAN X-ray unit with supervisor access.

How to set the login procedure

Configuration options for user login, including ISIS cards and access levels.

How to manage the access rights* for users with lower access level

Access to/access rights TIP* and OTS Xtrain* system

Granting or denying access to TIP and OTS XTrain system functions.

How to set operating options

How to select the image settings

Defining default image display, zoom settings, and screen saver options.

How to set the scanning functions

Configuring scanning parameters like operating mode, conveyor control, and image processing.

How to set the Automatic detection*

X-ACT:

Activating and configuring the X-ACT system for automatic threat detection.

Detection class:

Setting the detection class for explosives and drugs recognized by X-ACT.

High Density Alert:

Activating and configuring the High Density Alert function.

How to set the recheck* or the external image evaluation*

Transmit images

Activating or deactivating image transmission to recheck stations.

How to work with the IMS image store system*

How to operate the Online recording functions

Configuring and operating the online recording of scanned images for archiving.

How to configure the HI-TIPPLUS* and the aTIP* system

How to organize HI-TIPPLUS categories

Organizing threat image categories and subcategories for projection.

How to configure the OTS XTrain system*

How to organize training sessions

Organizing and managing training sessions and basic images.

How to calibrate* the HI-SCAN X-ray unit

How to calibrate the HI-SCAN X-ray unit

Monthly calibration of material detection and complete system calibration procedures.

Carry out complete calibration (fourfold calibration)

Executing a fourfold calibration process for the entire system.